EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access

Intraocular pressure measurement in keratoconus: a narrative review

Rafael Vidal Merola, Sebastião Cronemberger

International Journal of Ophthalmology · 18.08.2026 · 19 (8) · 1608-1617

DOI: 10.18240/ijo.2026.08.20 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift International Journal of Ophthalmology, erschienen am 18.08.2026. Verfasst von Rafael Vidal Merola und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Professor Antônio Carlos University Centre, UNIPAC, Juiz de Fora 36048-000, State of Minas Gerais, Brazil. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate measurement of intraocular pressure (IOP) is essential for the diagnosis and treatment of glaucoma. Keratoconus (KC) is an ectatic corneal disease, which evolves with progressive non-inflammatory thinning and is characterized by irregular astigmatism, and alteration of corneal biomechanics. There are many doubts regarding the best method to measure IOP in patients with KC, and, as far as we know, there are no manometric studies in patients with KC. It seems that IOP measurements made by Goldmann applanation tonometry (GAT) probably underestimate the real values in patients with KC. With the aim of obtaining more accurate measurements of IOP in KC, new devices were developed such as dynamic contour tonometry (DCT), ocular response analyzer (ORA) and corneal visualization scheimpflug technology (Corvis-ST). Possibly, DCT, corneal-compensated IOP (IOPcc)-ORA, and biomechanical corrected IOP (bIOP)-Corvis-ST can reduce some inaccuracies in IOP measurements related to thinning central corneal thickness and other biomechanical changes present in these patients. The different IOP measurement methods in KC are not interchangeable. Therefore, in KC we must always monitor IOP using the same device during follow-up. Furthermore, it is necessary to carefully study possible structural and functional changes that may occur in suspected cases of glaucoma.

Schlagwörter

Stichwörter der Autor:innen

Goldmann applanation tonometrycorneal biomechanicscorneal thicknessintraocular pressurekeratoconustonometer

Autor:innen und Institutionen

  • Faculty of Medicine, Professor Antônio Carlos University Centre, UNIPAC, Juiz de Fora 36048-000, State of Minas Gerais, Brazil.
  • Nassim Calixto Glaucoma Service of São Geraldo Eye Hospital, Clinic Hospital, Federal University of Minas Gerais, Belo Horizonte 30130-100, State of Minas Gerais, Brazil.

Zitieren

APA

Merola, R. V., & Cronemberger, S. (2026). Intraocular pressure measurement in keratoconus: a narrative review. International Journal of Ophthalmology, 19(8), 1608-1617. https://doi.org/10.18240/ijo.2026.08.20

Vancouver

Merola RV, Cronemberger S. Intraocular pressure measurement in keratoconus: a narrative review. International Journal of Ophthalmology. 2026;19(8):1608-1617. doi:10.18240/ijo.2026.08.20

BibTeX
@article{Merola2026,
  author = {Merola, Rafael Vidal and Cronemberger, Sebastião},
  title = {Intraocular pressure measurement in keratoconus: a narrative review},
  journal = {International Journal of Ophthalmology},
  year = {2026},
  volume = {19},
  number = {8},
  pages = {1608--1617},
  doi = {10.18240/ijo.2026.08.20}
}