Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI
IEEE Transactions on Biomedical Engineering · 2025-07 · 72 (7) · 2095-2104
DOI: 10.1109/tbme.2025.3534839 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025-07. Verfasst von Yiman Huang und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Signal Processing, Computer-Assisted, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Scientific and Technological Innovation 2030 Major Projects of Ministry of Science and Technology, National Natural Science Foundation of China, Fundamental Research Funds.
Abstract (Originalsprache)
OBJECTIVE: For low-field magnetic resonance imaging (MRI) in unshielded environment, existing methods have been proposed to eliminate electromagnetic interference (EMI) noise in each single radio-frequency (RF) receive coil. In the present study, we propose to use the EMI information from multiple MRI receive coils collectively in EMI denoising. METHODS: The proposed method leverages the information of inter-channel correlation, including EMI detectors and RF receive coils to remove EMI noise. Calibration signals from both EMI detectors and RF receivers are concatenated to determine a de-correlation matrix, which is then used to denoise MRI signals. RESULTS: Saline phantom and in vivo experiments demonstrated the efficacy of the proposed method in EMI elimination, showing that the proposed method outperformed advanced EMI elimination methods with up to 16.34% improvement in EMI noise removal percentage (NRP) and 1.58dB improvement in signal-to-noise ratio (SNR), along with reduced computational time. CONCLUSION: The proposed method effectively removes EMI noise and shows improved performance by using information from all receive coils. SIGNIFICANCE: This method allows for the design of multi-receive coils for low-field MRI such as phased-arrays, which have the potential to enhance the performance in noise removal and improve the SNR in MRI signal acquisition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Scientific and Technological Innovation 2030 Major Projects of Ministry of Science and Technology
- National Natural Science Foundation of China
- Fundamental Research Funds
- Zhejiang Provincial Natural Science Foundation of China
- Jiangsu Province Key Research and Development Program
Zitieren
APA
Huang, Y., Qu, S., Xie, Y., Wang, H., Zhang, X., & Zhang, X. (2025). Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI. IEEE Transactions on Biomedical Engineering, 72(7), 2095-2104. https://doi.org/10.1109/tbme.2025.3534839
Vancouver
Huang Y, Qu S, Xie Y, Wang H, Zhang X, Zhang X. Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI. IEEE Transactions on Biomedical Engineering. 2025;72(7):2095-2104. doi:10.1109/tbme.2025.3534839
BibTeX
@article{Huang2025,
author = {Huang, Yiman and Qu, Shuxian and Xie, Yushu and Wang, Hanlei and Zhang, Xinlin and Zhang, Xiaotong},
title = {Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
volume = {72},
number = {7},
pages = {2095--2104},
doi = {10.1109/tbme.2025.3534839}
}