Simultaneous Coherent and Displacement Compounding for 2-D Noninvasive Carotid Strain Imaging: A Proof of Principle Study
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3399836 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Moein Mozaffarzadeh und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Phantoms, Imaging, Carotid Arteries, Elasticity Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Gefördert von: ULTRA-X-TREME Project through the Netherlands Organisation for Scientific Research.
Abstract (Originalsprache)
Arteriosclerosis results from lipid buildup in artery walls, leading to plaque formation, and is a leading cause of death. Plaque rupture can cause blood clots that might lead to a stroke. Distinguishing plaque types is a challenge, but ultrasound (US) elastography can help by assessing plaque composition based on strain values. Since the artery has a circular structure, an accurate axial and lateral displacement strategy is needed to derive the radial and circumferential strains. A high-precision lateral displacement is challenging due to the lack of phase information in the lateral direction of the beamformed RF data. Previously, our group has developed a compounding technique in which the lateral displacement is estimated using triangulation of the axial displacement estimated from transmitting and beamforming US beams at ±20°. However, transmitting with a single plane wave will reduce signal-to-noise and contrast-to-noise ratio as well as lateral resolution. In this article, we combine our displacement compounding with coherent compounding. Instead of transmitting a single plane wave, multiple plane waves are transmitted at certain angles centered on the angle of the beamforming grids, and then, the backscattered wavefronts are beamformed and coherently compounded on the center of the transmit beams (-20°, +20°, and 0°). The numerical investigation using the GE9LD probe ( f0 = 5.32 MHz, pitch = 230 μ m, and width = 43.9 mm) led us to 19 plane waves spanning angles within -10° to 10° (with respect to center of the transmit beams), resulting in a total of 57 plane wave transmit (for three beamforming grids at 0° and ±20°). FIELD II simulations of a cylindrically shaped phantom (mimicking the carotid artery) at a signal-to-noise ratio (SNR) ≥ 20 dB show that the proposed method decreases the root-mean-square error (RMSE) of the lateral displacement and strain estimations by 40% and 45% compared to the previous method, respectively. The results of our experiments with a carotid artery phantom [made out of 10% polyvinyl alcohol (PVA)] show that the proposed method provides strain images with higher quality and more in agreement with the theory, with 26% lower standard deviation, especially at the peak systolic phase. The proposed method paves the path toward improved quality in vivo 2-D strain imaging using our displacement compounding technique and translating it to 3-D with a row-column array.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- ULTRA-X-TREME Project through the Netherlands Organisation for Scientific Research
Zitieren
APA
Mozaffarzadeh, M., Saris, A. E. C. M., Menssen, J., & de Korte, C. L. (2024). Simultaneous Coherent and Displacement Compounding for 2-D Noninvasive Carotid Strain Imaging: A Proof of Principle Study. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3399836
Vancouver
Mozaffarzadeh M, Saris AECM, Menssen J, de Korte CL. Simultaneous Coherent and Displacement Compounding for 2-D Noninvasive Carotid Strain Imaging: A Proof of Principle Study. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3399836
BibTeX
@article{Mozaffarzadeh2024,
author = {Mozaffarzadeh, Moein and Saris, Anne E C M and Menssen, Jan and de Korte, Chris L},
title = {Simultaneous Coherent and Displacement Compounding for 2-D Noninvasive Carotid Strain Imaging: A Proof of Principle Study},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3399836}
}
EUVIMED