EUVIMEDEUVIMED entdecken
Open Access

Multi‐Echo SSFP: A Method for Synthetic bSSFP MRI Contrast Without Banding Artifacts at High Field

Haotian Hong iD, Michael N Hoff iD, Wenchao Yang iD, Yiyun Dong iD, Zijian Zhou iD, Peng Hu iD

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1696-1708

DOI: 10.1002/mrm.70472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.06.2026. Verfasst von Haotian Hong und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, ShanghaiTech University, Shanghai, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Enhancement, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Science and Technology Commission of Shanghai Municipality, Beijing Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Balanced steady‐state free precession (bSSFP) is an important MRI sequence paradigm with a high signal‐to‐noise ratio (SNR) and inherent contrast, but suffers from banding artifacts due to inhomogeneity, especially in high‐field MRI. This study introduces a multi‐echo SSFP (MESS) sequence that synthesizes tunable bSSFP contrast without banding artifacts.

Methods

In bSSFP imaging, the observed signal can be formulated as a superposition of multiple echo orders, where off‐resonance phase divergences produce destructive interference, leading to dark bands. In contrast, the MESS sequence acquires these echoes separately. Extended phase graph (EPG) modeling demonstrates that by summing the echo magnitudes, MESS can reconstruct a signal that mirrors bSSFP contrast without banding artifacts. Image contrast can generally be tuned retrospectively by varying the virtual phase‐cycle increment . Phantom and in vivo experiments on a 5T scanner were performed to validate this approach.

Results

Phantom studies confirmed that MESS reconstructs the bSSFP contrast free of banding artifacts. In vivo scans further demonstrated robust artifact suppression while maintaining bSSFP‐like image contrast, and permitted flexible contrast variation by tuning .

Conclusion

MESS enables robust generation of banding artifact‐free bSSFP contrast in high‐field MRI by leveraging echo magnitude and virtual phase‐cycling, indicating a strong potential for robust image contrast synthesis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage EnhancementBrainImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedArtifactsPhantoms, ImagingAlgorithmsHumansSignal-To-Noise RatioReproducibility of ResultsSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

MESSbSSFPbanding artifactsmulti‐echo acquisitionsteady‐state

Autor:innen und Institutionen

  • School of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
  • Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
  • United Imaging Research, Shanghai, China.
  • Department of Physics, University of Washington, Seattle, Washington, USA.
  • State Key Laboratory of Advanced Medical Materials and Devices, Shanghai, China.
  • Shanghai Clinical Research and Trial Center, Shanghai, China.

ORCID-Profile: Haotian Hong, Michael N Hoff, Wenchao Yang, Yiyun Dong, Zijian Zhou, Peng Hu

Förderung

  • Science and Technology Commission of Shanghai Municipality
  • Beijing Natural Science Foundation
  • National Natural Science Foundation of China

Zitieren

APA

Hong, H., Hoff, M. N., Yang, W., Dong, Y., Zhou, Z., & Hu, P. (2026). Multi‐Echo SSFP: A Method for Synthetic bSSFP MRI Contrast Without Banding Artifacts at High Field. Magnetic Resonance in Medicine, 96(4), 1696-1708. https://doi.org/10.1002/mrm.70472

Vancouver

Hong H, Hoff MN, Yang W, Dong Y, Zhou Z, Hu P. Multi‐Echo SSFP: A Method for Synthetic bSSFP MRI Contrast Without Banding Artifacts at High Field. Magnetic Resonance in Medicine. 2026;96(4):1696-1708. doi:10.1002/mrm.70472

BibTeX
@article{Hong2026,
  author = {Hong, Haotian and Hoff, Michael N and Yang, Wenchao and Dong, Yiyun and Zhou, Zijian and Hu, Peng},
  title = {Multi‐Echo SSFP: A Method for Synthetic bSSFP MRI Contrast Without Banding Artifacts at High Field},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1696--1708},
  doi = {10.1002/mrm.70472}
}
Kostenlos starten →