EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design of Differential Single‐Block and Multi‐Block Presaturated Ultrashort Echo Time Pulse Sequences for Fast and Flexible Short‐ T 2 Imaging

Jason A Reich, Shannon L Taylor, Kevin D Harkins iD, Rachelle L Crescenzi, Erin L MacMillan iD, Rebecca E Feldman iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 711-726

DOI: 10.1002/mrm.70379 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 20.04.2026. Verfasst von Jason A Reich und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, Mathematics, Physics and Statistics, University of British Columbia, Kelowna, British Columbia, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NCATS NIH HHS, Natural Sciences and Engineering Research Council of Canada, Discovery Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Ultrashort echo time (UTE) techniques are essential for the magnetic resonance imaging of short‐ T 2 signals. Current UTE techniques are time‐consuming and often require the acquisition of an inflexible volume. In this work, we implement new UTE sequences—differential single‐block presaturated UTE (δSB‐UTE) and differential multi‐block presaturated UTE (δMB‐UTE)—that combine spatial presaturation and subtraction to enable simultaneous multi‐slice UTE acquisition with increased flexibility in field‐of‐view (FOV) and reduced scan times.

Methods

The sequences use a prepulse to presaturate blocks of magnetization and a whole‐volume excitation to enable UTE acquisition. By shifting the saturation blocks and subtracting subsequent acquisitions, two and four simultaneous slices can be imaged with the δSB‐UTE and δMB‐UTE sequences, respectively. Design trade‐offs were investigated in a phantom, and the sequences were used to image healthy volunteers at 3 T.

Results

The received signal strength increased as prepulse flip angle and saturation block shift increased. Slice thickness increased as prepulse flip angle, saturation block shift, and saturation block thickness decreased, and prepulse time·bandwidth product increased. The δSB‐UTE and δMB‐UTE sequences were used to image a 210 × 210 × 80 mm 3 in vivo volume with 1.0 × 1.0 × 4.0 mm 3 resolution in 2.66 and 1.45 min, respectively.

Conclusion

The δSB‐UTE and δMB‐UTE sequences can be used to capture short‐T 2 signal from the skull in multiple slices at the same time with an echo time of 0.18 ms. The δSB‐UTE and δMB‐UTE sequences enable the acquisition of a reduced through‐plane FOV and reduce scan times for imaging bone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedBrainHumansPhantoms, ImagingAlgorithmsSignal-To-Noise RatioSignal Processing, Computer-AssistedHealthy Volunteers

Stichwörter der Autor:innen

RF pulse designhumanpulse sequence designreduced field‐of‐viewshort‐T2 imagingsimultaneous multi‐sliceskull

Autor:innen und Institutionen

  • Department of Computer Science, Mathematics, Physics and Statistics, University of British Columbia, Kelowna, British Columbia, Canada.
  • Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • UBC MRI Research Centre, Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada.
  • Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada.

ORCID-Profile: Kevin D Harkins, Erin L MacMillan, Rebecca E Feldman

Förderung

  • NIH HHS
  • NCATS NIH HHS
  • Natural Sciences and Engineering Research Council of Canada, Discovery Grant
  • Michael Smith Health Research BC, Scholar Program
  • Canadian Foundation for Innovation, John R. Evans Leaders Fund
  • Natural Sciences and Engineering Research Council of Canada, Canada Graduate Scholarships - Doctoral Program
  • Natural Sciences and Engineering Research Council of Canada, Canada Graduate Scholarships - Michael smith Foreign Study Supplement
  • University of British Columbia, GoGlobal Self Directed Research Abroad Award

Zitieren

APA

Reich, J. A., Taylor, S. L., Harkins, K. D., Crescenzi, R. L., MacMillan, E. L., & Feldman, R. E. (2026). Design of Differential Single‐Block and Multi‐Block Presaturated Ultrashort Echo Time Pulse Sequences for Fast and Flexible Short‐ T 2 Imaging. Magnetic Resonance in Medicine, 96(2), 711-726. https://doi.org/10.1002/mrm.70379

Vancouver

Reich JA, Taylor SL, Harkins KD, Crescenzi RL, MacMillan EL, Feldman RE. Design of Differential Single‐Block and Multi‐Block Presaturated Ultrashort Echo Time Pulse Sequences for Fast and Flexible Short‐ T 2 Imaging. Magnetic Resonance in Medicine. 2026;96(2):711-726. doi:10.1002/mrm.70379

BibTeX
@article{Reich2026,
  author = {Reich, Jason A and Taylor, Shannon L and Harkins, Kevin D and Crescenzi, Rachelle L and MacMillan, Erin L and Feldman, Rebecca E},
  title = {Design of Differential Single‐Block and Multi‐Block Presaturated Ultrashort Echo Time Pulse Sequences for Fast and Flexible Short‐ T 2 Imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {711--726},
  doi = {10.1002/mrm.70379}
}
Kostenlos starten →