EUVIMEDEUVIMED entdecken
Crossref

Electrophysiology, Pathology, and Imaging of Pulsed Field Ablation of Scarred and Healthy Ventricles in Swine

Iwanari Kawamura iD, Vivek Y Reddy iD, Carlos G Santos-Gallego iD, Bingyan J Wang iD, Hina W Chaudhry, Eric D Buck iD, George Mavroudis, Samantha Jerrell, Christopher W Schneider, Molly Speltz iD, Srinivas R Dukkipati iD, Jacob S Koruth iD

Circulation: Arrhythmia and Electrophysiology · 2023-01 · 16 (1)

DOI: 10.1161/circep.122.011369 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2023-01. Verfasst von Iwanari Kawamura und 11 weiteren Autor:innen. Beteiligte Einrichtung: Helmsley Electrophysiology Center (I.K., V.Y.R., S.R.D., J.S.K.). Hauptthemen laut MEDLINE: Myocardial Infarction, Catheter Ablation, Tachycardia, Ventricular. Die Arbeit wurde bisher 59-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulsed field ablation (PFA) has recently been shown to penetrate ischemic scar, but details on its efficacy, risk of arrhythmias, and imaging insights are lacking. In a porcine model of myocardial scar, we studied the ability of ventricular PFA to penetrate scarred tissue, induce ventricular arrhythmias, and assess the influence of QRS gating during pulse delivery.

Methods

Of a total of 6 swine, 5 underwent coronary occlusion and 1 underwent radiofrequency ablation to create infarct scar and iatrogenic scar models, respectively. Two additional swine served as healthy controls. An 8 Fr focal PFA catheter was used to deliver bipolar, biphasic PFA (2.0 kV) lesions guided by electroanatomical mapping, fluoroscopy, and intracardiac echocardiography over both scarred and healthy myocardium. Swine underwent magnetic resonance imaging 2–7 days post-PFA.

Results

PFA successfully penetrated scar without significant difference in lesion depth between lesion at the infarct border (5.9±1.0 mm, n=41) and healthy myocardium (5.7±1.3 mm, n=26; P =0.53). PFA penetration of both infarct and iatrogenic radiofrequency abalation scar was observed in all examined sections. Sustained ventricular arrhythmias requiring defibrillation occurred in 4 of 187 (2.1%) ungated applications, whereas no ventricular arrhythmias occurred during gated PFA applications (0 of 64 [0%]). Dark-blood late-gadolinium–enhanced sequences allowed for improved endocardial border detection as well as lesion boundaries compared with conventional bright-blood late-gadolinium–enhanced sequences.

Conclusions

PFA penetrates infarct and iatrogenic scar successfully to create deep lesions. Gated delivery eliminates the occurrence of ventricular arrhythmias observed with ungated porcine PFA. Optimized magnetic resonance imaging sequences can be helpful in detecting lesion boundaries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial InfarctionCatheter AblationTachycardia, VentricularAnimalsSwineCicatrixGadoliniumArrhythmias, CardiacCardiac ElectrophysiologyIatrogenic Disease

Stichwörter der Autor:innen

Catheter ablationelectroporationmagnetic resonance imagingmyocardial infarctiontachycardiaventricular

Substanzen

Gadolinium

Autor:innen und Institutionen

  • Helmsley Electrophysiology Center (I.K., V.Y.R., S.R.D., J.S.K.).
  • Atherothrombosis Research Unit (C.G.S.-G.).
  • Cardiovascular Regenerative Medicine, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, NY (B.J.W., H.W.C.).
  • FARAPULSE, Menlo Park, CA (E.D.B., G.M., S.J., C.W.S.). R. & M. Speltz, LLC, Pathology Services, Stanchfield, MN.

ORCID-Profile: Iwanari Kawamura, Vivek Y Reddy, Carlos G Santos-Gallego, Bingyan J Wang, Eric D Buck, Molly Speltz, Srinivas R Dukkipati, Jacob S Koruth

Zitieren

APA

Kawamura, I., Reddy, V. Y., Santos-Gallego, C. G., Wang, B. J., Chaudhry, H. W., Buck, E. D., Mavroudis, G., Jerrell, S., Schneider, C. W., Speltz, M., Dukkipati, S. R., & Koruth, J. S. (2023). Electrophysiology, Pathology, and Imaging of Pulsed Field Ablation of Scarred and Healthy Ventricles in Swine. Circulation: Arrhythmia and Electrophysiology, 16(1). https://doi.org/10.1161/circep.122.011369

Vancouver

Kawamura I, Reddy VY, Santos-Gallego CG, Wang BJ, Chaudhry HW, Buck ED, et al. Electrophysiology, Pathology, and Imaging of Pulsed Field Ablation of Scarred and Healthy Ventricles in Swine. Circulation: Arrhythmia and Electrophysiology. 2023;16(1). doi:10.1161/circep.122.011369

BibTeX
@article{Kawamura2023,
  author = {Kawamura, Iwanari and Reddy, Vivek Y and Santos-Gallego, Carlos G and Wang, Bingyan J and Chaudhry, Hina W and Buck, Eric D and Mavroudis, George and Jerrell, Samantha and Schneider, Christopher W and Speltz, Molly and Dukkipati, Srinivas R and Koruth, Jacob S},
  title = {Electrophysiology, Pathology, and Imaging of Pulsed Field Ablation of Scarred and Healthy Ventricles in Swine},
  journal = {Circulation: Arrhythmia and Electrophysiology},
  year = {2023},
  volume = {16},
  number = {1},
  doi = {10.1161/circep.122.011369}
}
Kostenlos starten →