EUVIMEDEUVIMED entdecken
Crossref

Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients

Tomoya Tsuji iD, Hiroshi Yoshitomi, Munehiko Kowatari, Yoshihiko Tanimura

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae186 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Tomoya Tsuji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-…. Hauptthemen laut MEDLINE: Gamma Rays, Americium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A 241Am gamma (γ)-ray calibration field that meets the requirements for a γ-ray reference field as specified in the ISO 4037 standard series was established in the Facility of Radiation Standards of the Japan Atomic Energy Agency. The reference air kerma rates were measured using a reference ionization chamber calibrated by the N-80 quality X-ray calibration field of the national metrology standard in Japan and with a correction to account for differences in photon energy due to the calibration field. Conversion coefficients for the 241Am γ-ray calibration field, including those not listed in the ISO 4037 standard series, were calculated based on the measured γ-ray fluence rate spectra.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gamma RaysAmericiumCalibrationJapanReference StandardsRadiation DosageRadiation MonitoringRadiometryPhotons

Substanzen

AmericiumAmericium-241

Autor:innen und Institutionen

  • Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan.
  • Department of Radiation Measurement and Dose Assessment, National Institute for Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.

ORCID-Profile: Tomoya Tsuji

Zitieren

APA

Tsuji, T., Yoshitomi, H., Kowatari, M., & Tanimura, Y. (2024). Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae186

Vancouver

Tsuji T, Yoshitomi H, Kowatari M, Tanimura Y. Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae186

BibTeX
@article{Tsuji2024,
  author = {Tsuji, Tomoya and Yoshitomi, Hiroshi and Kowatari, Munehiko and Tanimura, Yoshihiko},
  title = {Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae186}
}
Kostenlos starten →