Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae186 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Tomoya Tsuji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-…. Hauptthemen laut MEDLINE: Gamma Rays, Americium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
A 241Am gamma (γ)-ray calibration field that meets the requirements for a γ-ray reference field as specified in the ISO 4037 standard series was established in the Facility of Radiation Standards of the Japan Atomic Energy Agency. The reference air kerma rates were measured using a reference ionization chamber calibrated by the N-80 quality X-ray calibration field of the national metrology standard in Japan and with a correction to account for differences in photon energy due to the calibration field. Conversion coefficients for the 241Am γ-ray calibration field, including those not listed in the ISO 4037 standard series, were calculated based on the measured γ-ray fluence rate spectra.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan.
- Department of Radiation Measurement and Dose Assessment, National Institute for Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
ORCID-Profile: Tomoya Tsuji
Zitieren
APA
Tsuji, T., Yoshitomi, H., Kowatari, M., & Tanimura, Y. (2024). Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae186
Vancouver
Tsuji T, Yoshitomi H, Kowatari M, Tanimura Y. Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae186
BibTeX
@article{Tsuji2024,
author = {Tsuji, Tomoya and Yoshitomi, Hiroshi and Kowatari, Munehiko and Tanimura, Yoshihiko},
title = {Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae186}
}
EUVIMED