Image quality in CT thorax: effect of altering reconstruction algorithm and tube load
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Bharti Kataria und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Linköping University, SE-581 85, Linköping, Sweden. Hauptthemen laut MEDLINE: Radiographic Image Interpretation, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Faculty at Linköping University, Avtal Läkarutbildning och Forskning, Forskning och Utveckling.
Abstract (Originalsprache)
Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-based IR algorithm (advanced modelled iterative reconstruction; ADMIRE) and dose on computed tomography thorax image quality. Dual-source scanner data were acquired at 20, 45 and 65 reference mAs in 20 patients. Images reconstructed with filtered back projection (FBP) and ADMIRE Strengths 3–5 were assessed independently by six radiologists and analysed using an ordinal logistic regression model. For all image criteria studied, the effects of tube load 20 mAs and all ADMIRE strengths were significant (p < 0.001) when compared to reference categories 65 mAs and FBP. Increase in tube load from 45 to 65 mAs showed image quality improvement in three of six criteria. Replacing FBP with ADMIRE significantly improves perceived image quality for all criteria studied, potentially permitting a dose reduction of almost 70% without loss in image quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Linköping University, SE-581 85, Linköping, Sweden.
- Department of Health, Medicine & Caring Sciences, Linköping University, SE-581 83 Linköping, Sweden.
- Center for Medical Image Science & Visualisation (CMIV), Linköping University, SE-581 83 Linköping, Sweden.
- Department of Medical Physics, Linköping University, SE-581 85 Linköping, Sweden.
- Department of Biomedical Engineering and Health Systems (MTH), KTH Royal Institute of Technology, SE-141 57 Stockholm, Sweden.
ORCID-Profile: Bharti Kataria, Michael Sandborg
Förderung
- Medical Faculty at Linköping University
- Avtal Läkarutbildning och Forskning
- Forskning och Utveckling
- Region financiered Forskning och Utbildning
- Swedish Heart-Lung Foundation
Zitieren
APA
Kataria, B., Woisetschläger, M., Nilsson Althén, J., Sandborg, M., & Smedby, Ö. (2024). Image quality in CT thorax: effect of altering reconstruction algorithm and tube load. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae005
Vancouver
Kataria B, Woisetschläger M, Nilsson Althén J, Sandborg M, Smedby Ö. Image quality in CT thorax: effect of altering reconstruction algorithm and tube load. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae005
BibTeX
@article{Kataria2024,
author = {Kataria, Bharti and Woisetschläger, Mischa and Nilsson Althén, Jonas and Sandborg, Michael and Smedby, Örjan},
title = {Image quality in CT thorax: effect of altering reconstruction algorithm and tube load},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae005}
}
EUVIMED