COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncac243 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Svea Deppe Mørup und 5 weiteren Autor:innen. Beteiligte Einrichtung: Health Sciences Research Centre, UCL University College, Niels Bohrs Alle 1, 5230 Odense M Denmark. Hauptthemen laut MEDLINE: Deep Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
To investigate the impact of combining the high-resolution (Hi-res) scan mode with deep learning image reconstruction (DLIR) algorithm in CT. Two phantoms (Catphan600® and Lungman, small, medium, large size) were CT scanned using combinations of Hi-res/standard mode and high-definition (HD)/standard kernels. Images were reconstructed with ASiR-V and three levels of DLIR. Spatial resolution, noise and contrast-to-noise ratio (CNR) were assessed. The radiation dose was recorded. The spatial resolution increased using Hi-res & HD. Image noise in the Catphan600® (69%) and the Lungman (10–70%) significantly increased when Hi-res & HD was applied. DLIR reduced the mean noise (54%). The CNR was reduced (64%) for Hi-res & HD. The radiation dose increased for both small (+70%) and medium (+43%) Lungman phantoms but decreased slightly for the large ones (−3%) when Hi-res was applied. In conclusion, the Hi-res scan mode improved the spatial resolution. The HD kernel significantly increased the image noise. DLIR improved the image noise and CNR and did not affect the spatial resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Health Sciences Research Centre, UCL University College, Niels Bohrs Alle 1, 5230 Odense M Denmark.
- Cardiology Research Department, Odense University Hospital, Baagøes Alle 15, 5700 Svendborg, Denmark.
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland.
- Department of Regional Health Research, University of Southern Denmark, J.B. Winsløws Vej 19, 3, 5000 Odense C, Denmark.
- Department of Radiology, Hospital Little Belt Kolding, Sygehusvej 24, 6000 Kolding, Denmark.
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Jutland, Esbjerg, Denmark.
ORCID-Profile: Svea Deppe Mørup, Helle Precht
Zitieren
APA
Mørup, S. D., Stowe, J., Precht, H., Kusk, M. W., Lambrechtsen, J., & Foley, S. J. (2023). COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac243
Vancouver
Mørup SD, Stowe J, Precht H, Kusk MW, Lambrechtsen J, Foley SJ. COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac243
BibTeX
@article{Mrup2023,
author = {Mørup, Svea Deppe and Stowe, John and Precht, Helle and Kusk, Martin Weber and Lambrechtsen, Jess and Foley, Shane J},
title = {COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncac243}
}
EUVIMED