Low Dose Contrast Enhanced CT Thorax Protocol: Comparison of Low Kilovoltage, Low Contrast Volume Using Iterative Reconstruction Technique with Standard Protocol
Ethiopian Journal of Health Sciences · 2025
DOI: 10.4314/ejhs.v35i2.2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Ethiopian Journal of Health Sciences, 2025. Verfasst von Cauvery Sirdeshpande und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, Ind…. Hauptthemen laut MEDLINE: Radiation Dosage, Contrast Media, Tomography, X-Ray Computed, Radiography, Thoracic. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Computed enhanced computed tomography (CECT) of the thorax is an effective imaging technique for diagnosing lung diseases. However, the increased use of CECT thorax scans has raised concerns regarding cancer risk and contrast-induced nephropathy (CIN). The iterative reconstruction (IR) method, specifically iDose4, enhances image quality (IQ) and reduces artifacts at low doses (LD). This study aimed to evaluate the image quality (IQ) and radiation dose (RD) of low-dose, low-volume (LD-LV) CECT thorax with iDose4, compared to standard dose (SD) CECT thorax (iDose4). METHODS: Group A consisted of 40 patients who underwent SD CECT thorax (120 kVp, 60 ml), while Group B included 40 patients who underwent LD-LV CECT thorax (80 kVp, 40 ml). All CECT thorax scans were performed using a 128-slice Incisive CT (Philips Healthcare Systems). A qualitative analysis of thoracic structures in both the lung and mediastinal windows was performed. Quantitative parameters, including Hounsfield units (HU) for the pulmonary artery (CTPA) and infraspinatus muscle (CTISM), noise (SD), and contrast-to-noise ratio (CNR), were also assessed. The Mann-Whitney U test and independent t-test were used to compare IQ and radiation dose between the two groups. RESULTS: Qualitative analysis of thoracic structures in the lung and mediastinal windows revealed no significant difference (p > 0.001) between the two groups. Quantitative parameters, such as CTPA, CTISM, and CNR, showed statistically significant differences (p < 0.001), with higher values observed in the LD-LV group compared to the SD group. The effective dose (ED) was reduced by 65.2% in the LD-LV group. CONCLUSION: Our LD-LV CECT thorax protocol using iDose4 demonstrated a significant reduction in effective dose and iodine contrast volume, while maintaining image quality and enhancing diagnostic confidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
- Department of Radiodiagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
Zitieren
APA
Sirdeshpande, C., Hebbar, K. D., & Pendem, S. (2025). Low Dose Contrast Enhanced CT Thorax Protocol: Comparison of Low Kilovoltage, Low Contrast Volume Using Iterative Reconstruction Technique with Standard Protocol. Ethiopian Journal of Health Sciences. https://doi.org/10.4314/ejhs.v35i2.2
Vancouver
Sirdeshpande C, Hebbar KD, Pendem S. Low Dose Contrast Enhanced CT Thorax Protocol: Comparison of Low Kilovoltage, Low Contrast Volume Using Iterative Reconstruction Technique with Standard Protocol. Ethiopian Journal of Health Sciences. 2025. doi:10.4314/ejhs.v35i2.2
BibTeX
@article{Sirdeshpande2025,
author = {Sirdeshpande, Cauvery and Hebbar, Karthikeya D and Pendem, Saikiran},
title = {Low Dose Contrast Enhanced CT Thorax Protocol: Comparison of Low Kilovoltage, Low Contrast Volume Using Iterative Reconstruction Technique with Standard Protocol},
journal = {Ethiopian Journal of Health Sciences},
year = {2025},
doi = {10.4314/ejhs.v35i2.2}
}
EUVIMED