Establishment of H p(3) calibration system for eye dose monitoring in Taiwan

Chiao-An Wu, Min-Chi Chiu, Tseng-Te Huang, Yi-Chun Lin, Chien-Hau Chu

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncad066 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Chiao-An Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Health Physics Division, Institute of Nuclear Energy Research, Taoyuan 325207, Taiwan. Hauptthemen laut MEDLINE: Radiation Protection, Nuclear Energy, Lens, Crystalline. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In response to the ICRP’s amending the occupational exposure limit for the eye lens, the Institute of Nuclear Energy Research (INER) established the Hp(3) calibration system for eye dose monitoring in Taiwan to accurately assess the dose received in the eye lens. INER employed the narrow-spectrum series radiation according to the ISO 4037 as the X-ray radiation qualities, and the measured half-value layer consistent with a 5% difference. The air kerma rate standard was determined by the self-made free air chamber, and through dose conversion coefficient referring to ISO 4037 to obtain the Hp(3) on an ISO cylinder phantom. Furthermore, the calibration system was provided as the characteristics tests for DOSIRIS headset dosemeters. Finally, the Hp(3) calibration system has been established in Taiwan, and it can be used to provide calibration services for eye lens dosemeters and be applied to the proficiency testing that will be held in 2023.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionNuclear EnergyLens, CrystallineCalibrationTaiwanX-RaysRadiation Dosage

Autor:innen und Institutionen

  • Health Physics Division, Institute of Nuclear Energy Research, Taoyuan 325207, Taiwan.

Zitieren

APA

Wu, C. A., Chiu, M. C., Huang, T. T., Lin, Y. C., & Chu, C. H. (2023). Establishment of H p(3) calibration system for eye dose monitoring in Taiwan. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad066

Vancouver

Wu CA, Chiu MC, Huang TT, Lin YC, Chu CH. Establishment of H p(3) calibration system for eye dose monitoring in Taiwan. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad066

BibTeX
@article{Wu2023,
  author = {Wu, Chiao-An and Chiu, Min-Chi and Huang, Tseng-Te and Lin, Yi-Chun and Chu, Chien-Hau},
  title = {Establishment of H p(3) calibration system for eye dose monitoring in Taiwan},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad066}
}
Kostenlos starten →