Fachartikel in der Zeitschrift Radiology Advances, 2024. Verfasst von Adam van Niekerk und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, 17177, Sweden. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Barncancerfonden, General Electric Healthcare.
Abstract (Originalsprache)
Background
Magnetic resonance imaging (MRI) is susceptible to motion artifacts, a particular challenge in pediatric imaging. External motion tracking devices and navigator techniques have been previously explored, but challenges persist necessitating sedation.
Purpose
To establish a new awake brain-MRI exam tolerated by children with diagnostic quality images. Materials and Methods Participants were prospectively recruited and investigated using an in-house developed multi-sequence scan called NeuroMix that produces T1-weighted, T2-weighted, T2*-weighted, T2-FLAIR, and diffusion-weighted images in under 3 minutes. Additionally, a self-created motion tracking device was attached to participants' foreheads to perform prospective motion correction (PMC) on 2D single-shot sequences that produce higher resolution images of the same contrasts as NeuroMix. Three neuroradiologists scored the completed series for artifacts. The effects of age group (<5 vs ≥5 years) and sequence type (NeuroMix vs PMC) were evaluated with a Chi2-test.
Results
Of the 64 participants recruited (mean age 6.7 years [2.7 standard deviation]) 58 completed their examination. Head motion recorded during PMC sequences revealed prevalent superior-inferior displacements [25% (67/293) exceeding 13.2 mm], and chin-up/down rotations [25% (67/293) exceeding 13.7°]. Sequence redundancy through NeuroMix and PMC scans resulted in 93% (54/58) of completed examinations having all series essential for producing an MRI-report rated as artifact-free, and therefore a report of high confidence in 84% (54/64) of participants. 22% (13/58) of completed exam reports could have been written using NeuroMix alone, the remaining required PMC- T2-weighted or T2-FLAIR sequences.
Conclusion
This protocol reliably provided diagnostic quality images and reports with high radiologist confidence and could reduce the use of procedure sedation in children.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, 17177, Sweden.
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, 17164, Sweden.
- MR Applied Science Laboratory Europe, GE Healthcare, Munich, 80807, Germany.
- Department of Women and Children's Health, Karolinska Institutet, Stockholm, 17177, Sweden.
ORCID-Profile: Adam van Niekerk
Förderung
- Barncancerfonden
- General Electric Healthcare
Zitieren
APA
van Niekerk, A., Svoboda, J., Aspelin, Å., Sprenger, T., Rydén, H., Norbeck, O., Avventi, E., Johansson, K., Rygaard, N., Lindberg, P., Wickström, R., Delgado, A. F., & Skare, S. (2024). Awake pediatric brain-MRI: a fast multi-sequence scan augmented with motion compensated single-shot 2D acquisitions. Radiology Advances. https://doi.org/10.1093/radadv/umae010
Vancouver
van Niekerk A, Svoboda J, Aspelin Å, Sprenger T, Rydén H, Norbeck O, et al. Awake pediatric brain-MRI: a fast multi-sequence scan augmented with motion compensated single-shot 2D acquisitions. Radiology Advances. 2024. doi:10.1093/radadv/umae010
BibTeX
@article{vanNiekerk2024,
author = {van Niekerk, Adam and Svoboda, Jan and Aspelin, Åsa and Sprenger, Tim and Rydén, Henric and Norbeck, Ola and Avventi, Enrico and Johansson, Katarina and Rygaard, Natalie and Lindberg, Peter and Wickström, Ronny and Delgado, Anna Falk and Skare, Stefan},
title = {Awake pediatric brain-MRI: a fast multi-sequence scan augmented with motion compensated single-shot 2D acquisitions},
journal = {Radiology Advances},
year = {2024},
doi = {10.1093/radadv/umae010}
}
EUVIMED