EUVIMEDEUVIMED entdecken
Open Access

Motion‐compensated low‐rank reconstruction for simultaneous structural and functional UTE lung MRI

Fei Tan iD, Xucheng Zhu iD, Marilynn Chan, Matthew A Zapala, Shreyas S Vasanawala, Frank Ong iD, Michael Lustig, Peder E Z Larson iD

Magnetic Resonance in Medicine · 2023-09 · 90 (3) · 1101-1113

DOI: 10.1002/mrm.29703 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.05.2023. Verfasst von Fei Tan und 7 weiteren Autor:innen. Beteiligte Einrichtung: UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, San Francisco, C…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Lung. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Three‐dimensional UTE MRI has shown the ability to provide simultaneous structural and functional lung imaging, but it is limited by respiratory motion and relatively low lung parenchyma SNR. The purpose of this paper is to improve this imaging by using a respiratory phase‐resolved reconstruction approach, named motion‐compensated low‐rank reconstruction (MoCoLoR), which directly incorporates motion compensation into a low‐rank constrained reconstruction model for highly efficient use of the acquired data. Theory and Methods The MoCoLoR reconstruction is formulated as an optimization problem that includes a low‐rank constraint using estimated motion fields to reduce the rank, optimizing over both the motion fields and reconstructed images. The proposed reconstruction along with XD and motion state–weighted motion‐compensation (MostMoCo) methods were applied to 18 lung MRI scans of pediatric and young adult patients. The data sets were acquired under free‐breathing and without sedation with 3D radial UTE sequences in approximately 5 min. After reconstruction, they went through ventilation analyses. Performance across reconstruction regularization and motion‐state parameters were also investigated.

Results

The in vivo experiments results showed that MoCoLoR made efficient use of the data, provided higher apparent SNR compared with state‐of‐the‐art XD reconstruction and MostMoCo reconstructions, and yielded high‐quality respiratory phase‐resolved images for ventilation mapping. The method was effective across the range of patients scanned.

Conclusion

The motion‐compensated low‐rank regularized reconstruction approach makes efficient use of acquired data and can improve simultaneous structural and functional lung imaging with 3D‐UTE MRI. It enables the scanning of pediatric patients under free‐breathing and without sedation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalLungYoung AdultHumansChildMagnetic Resonance ImagingRespiration

Stichwörter der Autor:innen

motion compensationpulmonary MRIultrashort echo time (UTE)ventilation imaging

Autor:innen und Institutionen

  • UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, San Francisco, California, USA.
  • Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA.
  • GE Healthcare, Sunnyvale, California, USA.
  • Pediatric Pulmonology, Department of Pediatrics, University of California, San Francisco, San Francisco, California, USA.
  • Pediatric Radiology, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA.
  • Pediatric Radiology, Department of Radiology, Stanford University, Stanford, California, USA.

ORCID-Profile: Fei Tan, Xucheng Zhu, Frank Ong, Peder E Z Larson

Förderung

  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Tan, F., Zhu, X., Chan, M., Zapala, M. A., Vasanawala, S. S., Ong, F., Lustig, M., & Larson, P. E. Z. (2023). Motion‐compensated low‐rank reconstruction for simultaneous structural and functional UTE lung MRI. Magnetic Resonance in Medicine, 90(3), 1101-1113. https://doi.org/10.1002/mrm.29703

Vancouver

Tan F, Zhu X, Chan M, Zapala MA, Vasanawala SS, Ong F, et al. Motion‐compensated low‐rank reconstruction for simultaneous structural and functional UTE lung MRI. Magnetic Resonance in Medicine. 2023;90(3):1101-1113. doi:10.1002/mrm.29703

BibTeX
@article{Tan2023,
  author = {Tan, Fei and Zhu, Xucheng and Chan, Marilynn and Zapala, Matthew A and Vasanawala, Shreyas S and Ong, Frank and Lustig, Michael and Larson, Peder E Z},
  title = {Motion‐compensated low‐rank reconstruction for simultaneous structural and functional UTE lung MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  volume = {90},
  number = {3},
  pages = {1101--1113},
  doi = {10.1002/mrm.29703}
}