Development of a spatially indexed dose–volume histogram for treatment plan evaluation
Journal of Radiation Research · 24.07.2026 · 67 (4) · 550-555
DOI: 10.1093/jrr/rrag050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiation Research, online erschienen am 15.07.2026. Verfasst von Hideharu Miura und 2 weiteren Autor:innen. Beteiligte Einrichtung: Hiroshima High-Precision Radiotherapy Cancer Center, 3-2-2, Futabanosato, Higashi-ku Hiroshima 732-0057, Japan. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research on Radiation Oncology from JASTRO.
Abstract (Originalsprache)
Conventional dose–volume histograms (DVHs) lack spatial information, a critical limitation in evaluating carotid artery sparing in laryngeal volumetric-modulated arc therapy (VMAT). We developed a spatially indexed DVH that integrates the distance between the planning target volume (PTV) and carotid arteries for a more comprehensive plan quality assessment. Three representative cases (distant, intermediate, proximal) were analyzed. For each carotid voxel, dose and minimum Euclidean distance to the PTV were calculated. A color-coded cumulative DVH was generated by mapping the mean dose-specific distance (MDD) to a color gradient (red: proximal, blue: distal). Spatial metrics at 35 Gy were derived: minimum distance (dmin,35Gy), mean dose-specific distance (MD35Gy) and V35Gy,10mm (volume ≥35 Gy within 10 mm of PTV surface). The spatially indexed DVH visually identified spatial risk transitions. In the distant case, V35Gy,10mm was negligible (0.1 cc and N/A). In the intermediate case, despite a low conventional V35Gy (0.9 and 1.8 cc), proximity metrics revealed high-risk areas with a dmin,35Gy of 3.2 mm and V35Gy,10mm of 0.8 and 1.4 cc. The proximal case showed the highest risk, with the DVH shifting to red above 30 Gy; nearly all V35Gy (2.4 and 2.3 cc) was within the 10-mm high-risk zone (V35Gy,10mm: 2.0 and 1.7 cc), with a dmin,35Gy of 2.2 and 1.4 mm. The spatially indexed DVH provides an intuitive method to evaluate the spatial relationship between high-dose regions and the PTV, facilitating better risk stratification and optimization in laryngeal VMAT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hiroshima High-Precision Radiotherapy Cancer Center, 3-2-2, Futabanosato, Higashi-ku Hiroshima 732-0057, Japan.
- Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minami-ku Hiroshima-shi, Hiroshima 734-8553, Japan.
ORCID-Profile: Hideharu Miura, Masahiro Kenjo
Förderung
- Research on Radiation Oncology from JASTRO
Zitieren
APA
Miura, H., Ozawa, S., & Kenjo, M. (2026). Development of a spatially indexed dose–volume histogram for treatment plan evaluation. Journal of Radiation Research, 67(4), 550-555. https://doi.org/10.1093/jrr/rrag050
Vancouver
Miura H, Ozawa S, Kenjo M. Development of a spatially indexed dose–volume histogram for treatment plan evaluation. Journal of Radiation Research. 2026;67(4):550-555. doi:10.1093/jrr/rrag050
BibTeX
@article{Miura2026,
author = {Miura, Hideharu and Ozawa, Shuichi and Kenjo, Masahiro},
title = {Development of a spatially indexed dose–volume histogram for treatment plan evaluation},
journal = {Journal of Radiation Research},
year = {2026},
volume = {67},
number = {4},
pages = {550--555},
doi = {10.1093/jrr/rrag050}
}
EUVIMED