EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A semi‐automated workflow for cohort‐wise preparation of radiotherapy data for dose‐response modeling, including autosegmentation of organs at risk

Louise Mövik iD, Anna Bäck, Kerstin Gunnarsson, Christian Jamtheim Gustafsson, Andreas Hallqvist, Niclas Pettersson

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Louise Mövik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Organs at Risk, Radiotherapy Planning, Computer-Assisted, Workflow, Deep Learning. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Varian Medical Systems, the King Gustaf V Jubilee Clinic Cancer Research Foundation, The Swedish state under the agreement between the Swedish government and the country councils, the ALF-agreements.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Preparing retrospective dose data for risk modeling using large study cohorts can be time consuming as it often requires patient‐wise manual interventions. This is especially the case when considering organs at risk (OARs) not systematically delineated historically. Therefore, we aimed to develop and test a semi‐automated workflow for cohort‐wise preparation of radiotherapy data from the oncology information system (OIS), including OAR autosegmentation, for risk modeling purposes.

Methods

A semi‐automated workflow, including cohort‐wise data extraction from a clinical OIS, cleanup, autosegmentation, quality controls (QCs), and data injection into a research OIS was iteratively developed using 106 patient cases. We evaluated two deep learning (DL)‐based methods and compared with four atlas‐based methods for autosegmentation of the proximal bronchial tree (PBT), the heart, and the esophagus that were possible to integrate into the workflow. One method was an in‐house DL‐based model using OARs manually contoured by experts for 100 cases. Geometric and dosimetric agreements with manually contoured OARs were evaluated for 20 independent cases. The final workflow was tested on 50 independent cases.

Results

The DL‐based methods were better than the atlas‐based at segmenting the PBT (mean Dice similarity coefficient (DSC) 0.81–0.83 versus 0.59–0.80) and the esophagus (mean DSC 0.76–0.77 versus 0.39–0.46). The methods performed similarly for the heart (mean DSC 0.90–0.95 (DL‐based) and 0.84–0.90 (atlas‐based)). Our in‐house autosegmentation model had the highest mean DSC for all OARs. The final version of the workflow successfully prepared data for 80% of the test cases without case‐specific manual interventions.

Conclusions

The semi‐automated workflow enabled efficient cohort‐wise preparation of OIS data for risk modeling purposes. Our in‐house DL‐based segmentation model outperformed the other methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Organs at RiskRadiotherapy Planning, Computer-AssistedWorkflowDeep LearningLung NeoplasmsHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetrospective StudiesDose-Response Relationship, RadiationAlgorithms

Stichwörter der Autor:innen

automationautosegmentationlarge‐scale studiesmodeling

Autor:innen und Institutionen

  • Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Therapeutic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden.
  • Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden.

ORCID-Profile: Louise Mövik

Förderung

  • Varian Medical Systems, the King Gustaf V Jubilee Clinic Cancer Research Foundation
  • The Swedish state under the agreement between the Swedish government and the country councils, the ALF-agreements

Zitieren

APA

Mövik, L., Bäck, A., Gunnarsson, K., Gustafsson, C. J., Hallqvist, A., & Pettersson, N. (2025). A semi‐automated workflow for cohort‐wise preparation of radiotherapy data for dose‐response modeling, including autosegmentation of organs at risk. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70152

Vancouver

Mövik L, Bäck A, Gunnarsson K, Gustafsson CJ, Hallqvist A, Pettersson N. A semi‐automated workflow for cohort‐wise preparation of radiotherapy data for dose‐response modeling, including autosegmentation of organs at risk. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70152