Volumetric Modulated Arc Therapy for lung cancer: Correlation between dose and volume

Yu Wang, Deying Xu, Yunfeng Liu, Xiaofeng Zhang, Liang Yu

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70781 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Yu Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Radiotherapy Center, Panjin Central Hospital, Panjin, Liaoning Province, China. Hauptthemen laut MEDLINE: Lung Neoplasms, Radiotherapy, Intensity-Modulated, Lung Volume Measurements, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In lung cancer radiotherapy, the volume of the lung receiving a dose above 20 Gy (V 20Gy ) and the mean lung dose are widely recognized dosimetric indicators for predicting radiation pneumonitis. However, there is currently no unified model to predict the minimum achievable values of V 20Gy and mean lung dose. In modern radiotherapy, the most advanced and widely used technology in mainstream medical linear accelerators is volumetric modulated arc therapy (VMAT). This article describes, based on linear accelerator VMAT, the clinical dependency of achievable dose‐to‐volume ratios.

Objective

To investigate the predictive effect of the ratio of the planning target volume (PTV) to lung volume (r) on lung V 20Gy and mean lung dose (MLD) in volumetric modulated arc therapy (VMAT) for lung cancer, with the aim of optimizing radiotherapy plans for lung cancer.

Methods

A total of 197 samples were used, including VMAT plans covering primary lung lesions and lymphatic drainage areas, of which 149 were used for training and 48 for testing. A retrospective analysis was conducted on the relationship between the r and MLD or V 20Gy in the plans, and function fitting was performed using the least squares method.

Results

The r ranged from 0.0112 to 0.2811. The R 2 values of the power function and logarithmic function of MLD versus r were 0.820 and 0.805, respectively, while the R 2 values of the power function and logarithmic function of V 20Gy versus r were 0.822 and 0.816, respectively. The residual of MLD is ± 200, and the residual of V 20Gy is ± 4%, with residuals distributed randomly.

Conclusion

The r showed good fitting results with the power and logarithmic functions of MLD or V 20Gy . During treatment plan creation and evaluation, the power or logarithmic function relationships can be used to predict MLD and V 20Gy in the treatment plan, thereby achieving the lowest possible lung dose while conforming to radiation principles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsRadiotherapy, Intensity-ModulatedLung Volume MeasurementsRadiotherapy Planning, Computer-AssistedTumor BurdenDose-Response Relationship, RadiationRetrospective StudiesOrgans at RiskHumansMaleFemaleAdult

Stichwörter der Autor:innen

linear acceleratorslung cancermean lung doseradiation therapyvolume ratio

Autor:innen und Institutionen

  • Radiotherapy Center, Panjin Central Hospital, Panjin, Liaoning Province, China.
  • Department of Radiotherapy, Kangbao County People's Hospital, Zhangjiakou, Hebei Province, China.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Wang, Y., Xu, D., Liu, Y., Zhang, X., & Yu, L. (2026). Volumetric Modulated Arc Therapy for lung cancer: Correlation between dose and volume. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70781

Vancouver

Wang Y, Xu D, Liu Y, Zhang X, Yu L. Volumetric Modulated Arc Therapy for lung cancer: Correlation between dose and volume. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70781

BibTeX
@article{Wang2026,
  author = {Wang, Yu and Xu, Deying and Liu, Yunfeng and Zhang, Xiaofeng and Yu, Liang},
  title = {Volumetric Modulated Arc Therapy for lung cancer: Correlation between dose and volume},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70781}
}
Kostenlos starten →