Evaluating dose distribution in prostate IMRT patients using deep learning: the influence of loss function on model performance
Physical and Engineering Sciences in Medicine · 2026
DOI: 10.1007/s13246-026-01703-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2026. Verfasst von Arezoo Kazemzadeh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran. Hauptthemen laut MEDLINE: Deep Learning, Radiotherapy, Intensity-Modulated, Prostatic Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
To estimate the influence of various loss functions on the performance of deep learning (DL) models for dose prediction in intensity-modulated radiotherapy (IMRT) for prostate cancer. A retrospective dataset comprising 110 prostate cancer patients was utilized. DL model was trained using various loss functions: mean absolute error (MAE), mean squared error (MSE), and combinations of MAE with predefined domain-specific knowledge, including dose-volume histogram (DVH) loss and moment loss function. The planned target volume (PTV) and dosimetric metrics for organs at risk (OARs) were used to assess the model's performance. A one-way analysis of variance (ANOVA) was applied to perform statistical comparisons between the clinical and predicted plans. In terms of dose deviations for OARs and PTV, the model trained with MAE plus moment loss performed better than models trained with MAE + DVH loss, MSE, or MAE. The MAE ± standard deviation (SD) between clinical and predicted dose distributions in the test cohort were (1.76 ± 0.5) Gy, (1.78 ± 0.5) Gy, (1.93 ± 0.6) Gy, and (2.02 ± 0.4) Gy for MAE + moment, MAE + DVH, MSE, and MAE models, respectively. Compared to the ground truth plans, the accuracy of all predicted plans was clinically acceptable. This study highlights how important loss function choice is to the optimization of DL-based prostate IMRT dose prediction models. The performance of the model is greatly improved by incorporating domain-specific knowledge into the loss function, which supports the possible practical application of such models for more precise and personalized radiation planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
- Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
- Head of Radiation Oncology Department, Milad Hospital, Isfahan, Iran.
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran. mbtavakoli@mui.ac.ir.
Zitieren
APA
Kazemzadeh, A., Rasti, R., Amouheidari, A., Abedi, I., & Tavakoli, M. B. (2026). Evaluating dose distribution in prostate IMRT patients using deep learning: the influence of loss function on model performance. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-026-01703-9
Vancouver
Kazemzadeh A, Rasti R, Amouheidari A, Abedi I, Tavakoli MB. Evaluating dose distribution in prostate IMRT patients using deep learning: the influence of loss function on model performance. Physical and Engineering Sciences in Medicine. 2026. doi:10.1007/s13246-026-01703-9
BibTeX
@article{Kazemzadeh2026,
author = {Kazemzadeh, Arezoo and Rasti, Reza and Amouheidari, Alireza and Abedi, Iraj and Tavakoli, Mohammad Bagher},
title = {Evaluating dose distribution in prostate IMRT patients using deep learning: the influence of loss function on model performance},
journal = {Physical and Engineering Sciences in Medicine},
year = {2026},
doi = {10.1007/s13246-026-01703-9}
}