Three-dimensional reconstruction of a small piece of Ce-doped lithium glass scintillator of an optical fiber-based neutron detector using microcomputed tomography technique
Journal of Radiation Research · 2025
DOI: 10.1093/jrr/rraf048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiation Research, 2025. Verfasst von Akihisa Ishikawa und 9 weiteren Autor:innen. Beteiligte Einrichtung: Research Group for Nuclear Sensing, Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195, …. Hauptthemen laut MEDLINE: Lithium, Glass, X-Ray Microtomography, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science KAKENHI.
Abstract (Originalsprache)
An optical fiber-based neutron detector is a real-time neutron monitor for an intense neutron field. A small piece of neutron scintillator, such as Ce-doped lithium glass (Li-glass), used in the detector has a random shape with a grain size of 200–400 μm. This causes shape-dependent effects on the detector response. However, it is difficult to control or determine its shape due to its small size. Here we propose a technique to characterize the fine structure of a small piece of scintillator using a microcomputed tomography (CT) system. To verify accuracy, the mass calculated based on the density of Li-glass and the volume extracted from the obtained CT image was compared to the mass measured in advance using an electronic balance. In the obtained CT images, the fine shape of the small piece of Li-glass was clearly visible, and no false signals from the surrounding components were observed. The calculated mass was in good agreement with the measured value, however, when the total number of projection images was 2000, a slight underestimation was observed. This was mitigated by increasing the number of projection images, and the difference between the calculated and measured mass was 1.6% when the number of the projection images was 3141. This was equivalent to the uncertainty of the measured mass. The proposed technique will be useful when high accuracy is needed, such as for medical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research Group for Nuclear Sensing, Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195, Japan.
- Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744, Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
- National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan.
- Department of Applied Energy, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8603, Japan.
ORCID-Profile: Akihisa Ishikawa, Akihiko Masuda, Tetsuro Matsumoto
Förderung
- Japan Society for the Promotion of Science KAKENHI
Zitieren
APA
Ishikawa, A., Segawa, M., Toh, Y., Watanabe, K., Masuda, A., Matsumoto, T., Yamazaki, A., Yoshihashi, S., Uritani, A., & Harano, H. (2025). Three-dimensional reconstruction of a small piece of Ce-doped lithium glass scintillator of an optical fiber-based neutron detector using microcomputed tomography technique. Journal of Radiation Research. https://doi.org/10.1093/jrr/rraf048
Vancouver
Ishikawa A, Segawa M, Toh Y, Watanabe K, Masuda A, Matsumoto T, et al. Three-dimensional reconstruction of a small piece of Ce-doped lithium glass scintillator of an optical fiber-based neutron detector using microcomputed tomography technique. Journal of Radiation Research. 2025. doi:10.1093/jrr/rraf048
BibTeX
@article{Ishikawa2025,
author = {Ishikawa, Akihisa and Segawa, Mariko and Toh, Yosuke and Watanabe, Kenichi and Masuda, Akihiko and Matsumoto, Tetsuro and Yamazaki, Atsushi and Yoshihashi, Sachiko and Uritani, Akira and Harano, Hideki},
title = {Three-dimensional reconstruction of a small piece of Ce-doped lithium glass scintillator of an optical fiber-based neutron detector using microcomputed tomography technique},
journal = {Journal of Radiation Research},
year = {2025},
doi = {10.1093/jrr/rraf048}
}
EUVIMED