EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Technical note: Measurement of the bunch structure of a clinical proton beam using a SiPM coupled to a plastic scintillator with an optical fiber

Miguel García Díez iD, Andrea Espinosa Rodriguez iD, Victor Sánchez Tembleque iD, Daniel Sánchez Parcerisa iD, Victor Valladolid Onecha, Juan A Vera Sanchez iD, Alejandro Mazal iD, Luis Mario Fraile iD, Jose Manuel Udias iD

Medical Physics · 2023

DOI: 10.1002/mp.16333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Miguel García Díez und 8 weiteren Autor:innen. Beteiligte Einrichtung: Grupo de Física Nuclear, EMFTEL & IPARCOS, Universidad Complutense de Madrid, CEI Moncloa, Madrid, Spain. Hauptthemen laut MEDLINE: Scintillation Counting, Proton Therapy. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Comunidad de Madrid, Spanish Government and EU Regional Funds, Spanish Ministerio de Educación, Cultura y Deporte.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent proposals of high dose rate plans in protontherapy as well as very short proton bunches may pose problems to current beam monitor systems. There is an increasing demand for real‐time proton beam monitoring with high temporal resolution, extended dynamic range and radiation hardness. Plastic scintillators coupled to optical fiber sensors have great potential in this context to become a practical solution towards clinical implementation.

Purpose

In this work, we evaluate the capabilities of a very compact fast plastic scintillator with an optical fiber readout by a SiPM and electronics sensor which has been used to provide information on the time structure at the nanosecond level of a clinical proton beam. Materials and methods A 3 × 3 × 3 mm 3 plastic scintillator (EJ‐232Q Eljen Technology) coupled to a 3 × 3 mm 2 SiPM (MicroFJ‐SMA‐30035, Onsemi) has been characterized with a 70 MeV clinical proton beam accelerated in a Proteus One synchrocyclotron. The signal was read out by a high sampling rate oscilloscope (5 GS/s). By exposing the sensor directly to the proton beam, the time beam profile of individual spots was recorded.

Results

Measurements of detector signal have been obtained with a time sampling period of 0.8 ns. Proton bunch period (16 ns), spot (10 μs) and interspot (1 ms) time structures could be observed in the time profile of the detector signal amplitude. From this, the RF frequency of the accelerator has been extracted, which is found to be 64 MHz.

Conclusions

The proposed system was able to measure the fine time structure of a clinical proton accelerator online and with ns time resolution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Scintillation CountingProton TherapyOptical FibersProtonsPlastics

Stichwörter der Autor:innen

FLASH-RTRF frequencyfine time structure measurementplastic scintillator fiber optic detectortime resolution

Substanzen

ProtonsPlastics

Autor:innen und Institutionen

  • Grupo de Física Nuclear, EMFTEL & IPARCOS, Universidad Complutense de Madrid, CEI Moncloa, Madrid, Spain.
  • Instituto de Investigación del Hospital Clínico San Carlos (IdISSC), Ciudad Universitaria, Madrid, Spain.
  • Centro de Protonterapia Quironsalud, Madrid, Spain.

ORCID-Profile: Miguel García Díez, Andrea Espinosa Rodriguez, Victor Sánchez Tembleque, Daniel Sánchez Parcerisa, Juan A Vera Sanchez, Alejandro Mazal, Luis Mario Fraile, Jose Manuel Udias

Förderung

  • Comunidad de Madrid
  • Spanish Government and EU Regional Funds
  • Spanish Ministerio de Educación, Cultura y Deporte

Zitieren

APA

García Díez, M., Espinosa Rodriguez, A., Sánchez Tembleque, V., Sánchez Parcerisa, D., Valladolid Onecha, V., Vera Sanchez, J. A., Mazal, A., Fraile, L. M., & Udias, J. M. (2023). Technical note: Measurement of the bunch structure of a clinical proton beam using a SiPM coupled to a plastic scintillator with an optical fiber. Medical Physics. https://doi.org/10.1002/mp.16333

Vancouver

García Díez M, Espinosa Rodriguez A, Sánchez Tembleque V, Sánchez Parcerisa D, Valladolid Onecha V, Vera Sanchez JA, et al. Technical note: Measurement of the bunch structure of a clinical proton beam using a SiPM coupled to a plastic scintillator with an optical fiber. Medical Physics. 2023. doi:10.1002/mp.16333

BibTeX
@article{GarcaDez2023,
  author = {García Díez, Miguel and Espinosa Rodriguez, Andrea and Sánchez Tembleque, Victor and Sánchez Parcerisa, Daniel and Valladolid Onecha, Victor and Vera Sanchez, Juan A and Mazal, Alejandro and Fraile, Luis Mario and Udias, Jose Manuel},
  title = {Technical note: Measurement of the bunch structure of a clinical proton beam using a SiPM coupled to a plastic scintillator with an optical fiber},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16333}
}
Kostenlos starten →