EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characteristics of a Miniature Fiber-Optic Inorganic Scintillator Detector for Electron-Beam Therapy Dosimetry

Zhuang Qin iD, Ziyin Chen iD, Bo He iD, Weimin Sun iD, Yachen Gao iD

Sensors · 2025

DOI: 10.3390/s25144243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Zhuang Qin und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic Engineering, Heilongjiang University, Harbin 150080, China. Hauptthemen laut MEDLINE: Electrons, Scintillation Counting, Radiometry, Fiber Optic Technology. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundamental Research Funds for the Higher Institutions in Heilongjiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past few decades, electron beams have been widely used to treat malignant and benign tumors located in the superficial regions of patients. This study utilized an inorganic scintillator (Gd2O2S:Tb)-based radiation detector to test its response characteristics in an electron-beam radiotherapy environment, in order to determine the application potential of this detector in electron-beam therapy. Owing to the extremely high time resolution of this inorganic scintillator detector (ISD), it is even capable of measuring the pulse information of electron beams generated by the accelerator. The results indicate that for certain accelerator models, such as the IX3937, the pulse pattern of the output electron beam is notably different from that during the output of X-rays, showing no significant periodicity. The experimental results also demonstrate that this ISD exhibits excellent repeatability and dose linearity (R2 of 0.9993) when measuring electron beams. Finally, the PDD (Percentage Depth Dose) curves and OAR (Off-Axis Ratio) curves of the ISD were also tested under electron-beam conditions at 6 MeV and 9 MeV, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectronsScintillation CountingRadiometryFiber Optic TechnologyHumansOptical Fibers

Stichwörter der Autor:innen

electron-beamfiber sensorinorganic scintillator

Autor:innen und Institutionen

  • School of Electronic Engineering, Heilongjiang University, Harbin 150080, China.
  • Comprehensive Cancer Center, First Affiliated Hospital of Harbin Medical University, Harbin 150001, China.
  • Key Lab of In-Fiber Integrated Optics, Ministry Education of China, Harbin Engineering University, Harbin 150001, China.

ORCID-Profile: Zhuang Qin, Ziyin Chen, Bo He, Weimin Sun, Yachen Gao

Förderung

  • Fundamental Research Funds for the Higher Institutions in Heilongjiang Province

Zitieren

APA

Qin, Z., Chen, Z., He, B., Sun, W., & Gao, Y. (2025). Characteristics of a Miniature Fiber-Optic Inorganic Scintillator Detector for Electron-Beam Therapy Dosimetry. Sensors. https://doi.org/10.3390/s25144243

Vancouver

Qin Z, Chen Z, He B, Sun W, Gao Y. Characteristics of a Miniature Fiber-Optic Inorganic Scintillator Detector for Electron-Beam Therapy Dosimetry. Sensors. 2025. doi:10.3390/s25144243

BibTeX
@article{Qin2025,
  author = {Qin, Zhuang and Chen, Ziyin and He, Bo and Sun, Weimin and Gao, Yachen},
  title = {Characteristics of a Miniature Fiber-Optic Inorganic Scintillator Detector for Electron-Beam Therapy Dosimetry},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25144243}
}
Kostenlos starten →