EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improvement of deep learning-based dose conversion accuracy to a Monte Carlo algorithm in proton beam therapy for head and neck cancers

Ryohei Kato iD, Noriyuki Kadoya iD, Takahiro Kato iD, Ryota Tozuka, Shuta Ogawa, Masao Murakami iD, Keiichi Jingu iD

Journal of Radiation Research · 2025

DOI: 10.1093/jrr/rraf019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiation Research, 2025. Verfasst von Ryohei Kato und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan. Hauptthemen laut MEDLINE: Proton Therapy, Monte Carlo Method, Head and Neck Neoplasms, Deep Learning. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study is aimed to clarify the effectiveness of the image-rotation technique and zooming augmentation to improve the accuracy of the deep learning (DL)-based dose conversion from pencil beam (PB) to Monte Carlo (MC) in proton beam therapy (PBT). We adapted 85 patients with head and neck cancers. The patient dataset was randomly divided into 101 plans (334 beams) for training/validation and 11 plans (34 beams) for testing. Further, we trained a DL model that inputs a computed tomography (CT) image and the PB dose in a single-proton field and outputs the MC dose, applying the image-rotation technique and zooming augmentation. We evaluated the DL-based dose conversion accuracy in a single-proton field. The average γ-passing rates (a criterion of 3%/3 mm) were 80.6 ± 6.6% for the PB dose, 87.6 ± 6.0% for the baseline model, 92.1 ± 4.7% for the image-rotation model, and 93.0 ± 5.2% for the data-augmentation model, respectively. Moreover, the average range differences for R90 were − 1.5 ± 3.6% in the PB dose, 0.2 ± 2.3% in the baseline model, −0.5 ± 1.2% in the image-rotation model, and − 0.5 ± 1.1% in the data-augmentation model, respectively. The doses as well as ranges were improved by the image-rotation technique and zooming augmentation. The image-rotation technique and zooming augmentation greatly improved the DL-based dose conversion accuracy from the PB to the MC. These techniques can be powerful tools for improving the DL-based dose calculation accuracy in PBT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyMonte Carlo MethodHead and Neck NeoplasmsDeep LearningAlgorithmsRadiation DosageHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed

Stichwörter der Autor:innen

Monte Carlodeep learninghead and neckpencil beam algorithmproton therapy

Autor:innen und Institutionen

  • Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan.
  • Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryou-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima, 960-8516, Japan.
  • Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-city, Yamanashi, 409-3898, Japan.
  • Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan.

ORCID-Profile: Ryohei Kato, Noriyuki Kadoya, Takahiro Kato, Masao Murakami, Keiichi Jingu

Zitieren

APA

Kato, R., Kadoya, N., Kato, T., Tozuka, R., Ogawa, S., Murakami, M., & Jingu, K. (2025). Improvement of deep learning-based dose conversion accuracy to a Monte Carlo algorithm in proton beam therapy for head and neck cancers. Journal of Radiation Research. https://doi.org/10.1093/jrr/rraf019

Vancouver

Kato R, Kadoya N, Kato T, Tozuka R, Ogawa S, Murakami M, et al. Improvement of deep learning-based dose conversion accuracy to a Monte Carlo algorithm in proton beam therapy for head and neck cancers. Journal of Radiation Research. 2025. doi:10.1093/jrr/rraf019

BibTeX
@article{Kato2025,
  author = {Kato, Ryohei and Kadoya, Noriyuki and Kato, Takahiro and Tozuka, Ryota and Ogawa, Shuta and Murakami, Masao and Jingu, Keiichi},
  title = {Improvement of deep learning-based dose conversion accuracy to a Monte Carlo algorithm in proton beam therapy for head and neck cancers},
  journal = {Journal of Radiation Research},
  year = {2025},
  doi = {10.1093/jrr/rraf019}
}
Kostenlos starten →