EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep learning‐based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices

Dong Yang iD, Jiawei Fan, Yu Wenliang, Jiazhou Wang iD, Zihan Sun, Weigang Hu

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Dong Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shangh…. Hauptthemen laut MEDLINE: Deep Learning, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Head and Neck Neoplasms. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Pujiang Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose Electronic portal imaging devices (EPIDs) have been used as an in vivo dosimetry method to identify treatment discrepancies by comparing planned and predicted 3D dose. The purpose of this study was to develop and evaluate a deep learning‐based framework for reconstructing three‐dimensional (3D) patient dose distributions directly from electronic portal imaging device (EPID) images and planning CT, without relying on Monte Carlo simulation or conventional back‐projection methods. Materials and methods A Res‐UNet architecture was trained using 512 beam fields from 60 head and neck IMRT patients to predict beam‐specific dose slices from corresponding EPID images and CT data. For each beam, predicted dose slices were assembled into a 3D volume and summed across all beams to reconstruct the full patient dose. The model was evaluated on 10 independent cases using voxel‐wise mean absolute error (MAE), mean squared error (MSE), slice‐wise dose difference, 3D gamma analysis (global normalization, 10% low‐dose threshold) with criteria of 3%/3 mm, and dose‐volume histogram (DVH) comparisons. Statistical significance was assessed using the Wilcoxon signed‐rank test.

Results

The model achieved a mean voxel‐wise MAE of 0.163 Gy, with over 95% of voxels with MAE < 2 Gy. The average slice‐level dose difference was 1.186 Gy, with localized underestimation observed in high‐dose gradient regions. The overall global 3D gamma passing rates were 90.67% for the 3%/3 mm criterion. DVH comparisons showed no statistically significant differences for most targets and organs‐at‐risk, except for D 2% of the left lens ( p = 0.020) and D mean of the parotid glands ( p = 0.012), which demonstrated statistically significant differences. The average reconstruction time was 15 s per beam.

Conclusion

The proposed framework demonstrates the feasibility of fast and patient‐specific 3D dose reconstruction using EPID and CT data without complex physical modeling. Under the predefined acceptance criterion (≥95% of voxels with MAE < 2 Gy), 7 out of 10 test cases met the standard. Although high‐gradient regions remain challenging and gamma passing rates for the 3%/3 mm criterion were slightly lower than in some prior studies, the method offers sufficient accuracy for many quality assurance applications and provides a foundation for future integration into online adaptive radiotherapy workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHead and Neck NeoplasmsImaging, Three-DimensionalImage Processing, Computer-AssistedHumansRadiotherapy DosageTomography, X-Ray ComputedOrgans at RiskAlgorithmsMonte Carlo MethodRadiometry

Stichwörter der Autor:innen

deep learning (DL)dose reconstructionelectronic portal imaging device (EPID)patient specific quality assurancetransit dosimetry

Autor:innen und Institutionen

  • Department of Radiation Oncology, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
  • Department of Radiation Oncology, Quzhou People' s Hospital, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou, China.
  • Department of Radiation Oncology, The first affiliated hospital, Zhejiang University school of medicine, Hangzhou, China.

ORCID-Profile: Dong Yang, Jiazhou Wang

Förderung

  • Shanghai Pujiang Programme

Zitieren

APA

Yang, D., Fan, J., Wenliang, Y., Wang, J., Sun, Z., & Hu, W. (2025). Deep learning‐based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70328

Vancouver

Yang D, Fan J, Wenliang Y, Wang J, Sun Z, Hu W. Deep learning‐based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70328

BibTeX
@article{Yang2025,
  author = {Yang, Dong and Fan, Jiawei and Wenliang, Yu and Wang, Jiazhou and Sun, Zihan and Hu, Weigang},
  title = {Deep learning‐based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70328}
}
Kostenlos starten →