EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure

Nishiki Matsubayashi, Naonori Hu, Takushi Takata, Akinori Sasaki, Hiroaki Kumada, Satoshi Nakamura, Akihiko Masuda, Hiroki Tanaka

Journal of Radiation Research · 22.01.2025 · 66 (1) · 10-15

DOI: 10.1093/jrr/rrae089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiation Research, online erschienen am 19.11.2024. Verfasst von Nishiki Matsubayashi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Particle Radiation Oncology Research Center, Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2, Asashiro-Nishi, Kumatori-ch…. Hauptthemen laut MEDLINE: Boron Neutron Capture Therapy, Phantoms, Imaging, Quality Assurance, Health Care. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Promotion of Joint International Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accelerator-based boron neutron capture therapy (BNCT) system has been approved for specific cases covered by health insurance, and clinical trials for new cases in Japan are currently being conducted on other systems. Owing to the progress of accelerator-based BNCT, the operation of medical physics must be rendered more efficient. A water phantom is used for the quality assurance (QA) of the BNCT beam output procedure; however, a solid phantom is preferred for routine QA because of its ease of use. Additionally, because water phantoms cannot be readily used in some facilities owing to structural problems, solid phantoms are preferred for unified measurements at different facilities to compare beam outputs. In this study, we perform irradiation tests using an acrylic phantom and verify that an acrylic phantom can be used for QA. The distribution of thermal neutron flux and gamma-ray dose rate inside the acrylic phantom are evaluated through experiments and simulations. The results indicate that the acrylic phantom is suitable for routine QA and for comparing beam outputs among different systems. In the future, the same irradiation tests will be conducted at other facilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boron Neutron Capture TherapyPhantoms, ImagingQuality Assurance, Health CareQuality ControlRadiotherapy DosageHumans

Stichwörter der Autor:innen

BNCTgamma-rayneutronphantomquality assurance

Autor:innen und Institutionen

  • Particle Radiation Oncology Research Center, Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2, Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka 590-0494, Japan.
  • Kansai BNCT Medical Center, Educational Foundation of Osaka Medical and Pharmaceutical University, Daigakumachi, Takatsuki, Osaka 569-0801, Japan.
  • Institute of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki 305-8575, Japan.
  • Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
  • National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan.

Förderung

  • Promotion of Joint International Research

Zitieren

APA

Matsubayashi, N., Hu, N., Takata, T., Sasaki, A., Kumada, H., Nakamura, S., Masuda, A., & Tanaka, H. (2025). Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure. Journal of Radiation Research, 66(1), 10-15. https://doi.org/10.1093/jrr/rrae089

Vancouver

Matsubayashi N, Hu N, Takata T, Sasaki A, Kumada H, Nakamura S, et al. Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure. Journal of Radiation Research. 2025;66(1):10-15. doi:10.1093/jrr/rrae089

BibTeX
@article{Matsubayashi2025,
  author = {Matsubayashi, Nishiki and Hu, Naonori and Takata, Takushi and Sasaki, Akinori and Kumada, Hiroaki and Nakamura, Satoshi and Masuda, Akihiko and Tanaka, Hiroki},
  title = {Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure},
  journal = {Journal of Radiation Research},
  year = {2025},
  volume = {66},
  number = {1},
  pages = {10--15},
  doi = {10.1093/jrr/rrae089}
}
Kostenlos starten →