EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dosimetric commissioning of a high-resolution CMOS 2D detector array for patient-specific QA of single-isocenter multi-target VMAT stereotactic radiosurgery

Ching-Ling Teng, Shih-Chi Lin, Dale Michael Lovelock, Seng Boh Lim

Journal of Radiation Research · 2024

DOI: 10.1093/jrr/rrae080 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiation Research, 2024. Verfasst von Ching-Ling Teng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Oncology, Mount Sinai West, 1000 10th Avenue, New York, NY 10019, USA. Hauptthemen laut MEDLINE: Radiosurgery, Radiometry, Semiconductors, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIH/NCI Cancer Center Support.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stereotactic radiosurgery (SRS) using the single-isocenter-multiple-target (SIMT) technique by volumetric modulated arc therapy is increasingly popular for treating multiple brain metastases. However, the complex nature of SIMT SRS necessitates rigorous patient-specific quality assurance (PSQA). This study presents a multi-institutional dosimetric commissioning of a high-resolution complementary metal oxide semiconductor (CMOS) 2D detector array, the myQA SRS device for SIMT SRS PSQA. Basic dosimetric properties such as dose-rate, field-size, energy and angular dependencies were characterized for the CMOS detectors. Additionally, gamma index analyses were performed between the measured dose and the films for nine simulated and clinical plans. The results showed that the CMOS detector was dose-rate, field-size, energy and beam-angle dependent. Specific to SIMT SRS, angular dependence on gantry rotations was invariant to couch rotations but was sensitive to off-isocenter distances. With appropriate dose calibration and angular corrections, myQA SRS showed a high dosimetric correlation with films. The average gamma index pass rates were 99.9 ± 0.03% and 99.2 ± 1.1% at 3%/2 mm/10%thr(global) and 1 mm/1%/10%thr(local) criteria, respectively. The average dose difference between myQA SRS and films was 0.4 ± 1.3%. In conclusion, the CMOS 2D detector array has demonstrated its potential as a reliable tool for PSQA for SIMT SRS. The excellent dosimetric agreement with the films was consistent in multiple institutions, further validating the dosimetric accuracy and reproducibility. It provides a timely alternative to film dosimetry for commissioning and quality assurance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiometrySemiconductorsRadiotherapy, Intensity-ModulatedHumansQuality Assurance, Health CareRadiotherapy DosageRadiotherapy Planning, Computer-AssistedCalibration

Stichwörter der Autor:innen

CMOS 2D diode arraymyQA SRSpatient-specific QAradiochromic film dosimetrysingle isocenter multiple target SIMTstereotactic radiosurgery SRS

Autor:innen und Institutionen

  • Radiation Oncology, Mount Sinai West, 1000 10th Avenue, New York, NY 10019, USA.
  • Biomedical Engineering, One University Avenue, University of Massachusetts Lowell, Lowell, MA, 01854, USA.
  • Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065, USA.
  • Radiation Oncology, The Mount Sinai Hospital, 1158 5th Avenue, New York, NY 10029, USA.

Förderung

  • NCI NIH HHS
  • NIH/NCI Cancer Center Support

Zitieren

APA

Teng, C. L., Lin, S. C., Lovelock, D. M., & Lim, S. B. (2024). Dosimetric commissioning of a high-resolution CMOS 2D detector array for patient-specific QA of single-isocenter multi-target VMAT stereotactic radiosurgery. Journal of Radiation Research. https://doi.org/10.1093/jrr/rrae080

Vancouver

Teng CL, Lin SC, Lovelock DM, Lim SB. Dosimetric commissioning of a high-resolution CMOS 2D detector array for patient-specific QA of single-isocenter multi-target VMAT stereotactic radiosurgery. Journal of Radiation Research. 2024. doi:10.1093/jrr/rrae080

BibTeX
@article{Teng2024,
  author = {Teng, Ching-Ling and Lin, Shih-Chi and Lovelock, Dale Michael and Lim, Seng Boh},
  title = {Dosimetric commissioning of a high-resolution CMOS 2D detector array for patient-specific QA of single-isocenter multi-target VMAT stereotactic radiosurgery},
  journal = {Journal of Radiation Research},
  year = {2024},
  doi = {10.1093/jrr/rrae080}
}
Kostenlos starten →