Assessing the sensitivity and suitability of a range of detectors for SIMT PSQA

Leon Dunn, Alessia Tamborriello, Brindha Subramanian, Xiaolei Xu, Tyrone Te Ruruku

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Leon Dunn und 4 weiteren Autor:innen. Beteiligte Einrichtung: GenesisCare Berwick, St John of God Berwick Specialist Centre, Berwick, Victoria, Australia. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Brain Neoplasms, Radiosurgery. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Single‐isocenter multi‐target intracranial stereotactic radiotherapy (SIMT) is an effective treatment for brain metastases with complex treatment plans and delivery optimization necessitating rigorous quality assurance. This work aims to assess five methods for quality assurance of SIMT treatment plans in terms of their suitability and sensitivity to delivery errors.

Methods

Sun Nuclear ArcCHECK and SRS MapCHECK, GafChromic EBT Radiochromic Film, machine log files, and Varian Portal Dosimetry were all used to measure 15 variations of a single SIMT plan. Variations of the original plan were created with Python. They comprised various degrees of systematic MLC offsets per leaf up to 2 mm, random per‐leaf variations with differing minimum and maximum magnitudes, simulated collimator, and dose miscalibrations (MU scaling). The erroneous plans were re‐imported into Eclipse and plan‐quality degradation was assessed by comparing each plan variation to the original clinical plan in terms of the percentage of clinical goals passing relative to the original plan. Each erroneous plan could be then ranked by the plan‐quality degradation percentage following recalculation in the TPS so that the effects of each variation could be correlated with γ pass rates and detector suitability. Results & conclusions It was found that 2%/1 mm is a good starting point for the ArcCHECK, Portal Dosimetry, and the SRS MapCHECK methods, respectively, and provides clinically relevant error detection sensitivity. Looser dose criteria of 5%/1 mm or 5%/1.5 mm are suitable for film dosimetry and log‐file‐based methods. The statistical methods explored can be expanded to other areas of patient‐specific QA and detector assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy DosageBrain NeoplasmsRadiosurgeryQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedHumansParticle AcceleratorsRadiometryAlgorithms

Stichwörter der Autor:innen

ArcCHECKPSQASIMTSRSSRS MapCHECKSRTdetectorexternal beamfilmlog fileportal dosimetryquality assurancesensitivitystereotactic

Autor:innen und Institutionen

  • GenesisCare Berwick, St John of God Berwick Specialist Centre, Berwick, Victoria, Australia.
  • GenesisCare Frankston, Frankston Public Surgical Centre, Frankston, Victoria, Australia.
  • GenesisCare Ringwood, Ringwood Private Hospital, Ringwood East, Victoria, Australia.

Zitieren

APA

Dunn, L., Tamborriello, A., Subramanian, B., Xu, X., & Ruruku, T. T. (2024). Assessing the sensitivity and suitability of a range of detectors for SIMT PSQA. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14343

Vancouver

Dunn L, Tamborriello A, Subramanian B, Xu X, Ruruku TT. Assessing the sensitivity and suitability of a range of detectors for SIMT PSQA. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14343

BibTeX
@article{Dunn2024,
  author = {Dunn, Leon and Tamborriello, Alessia and Subramanian, Brindha and Xu, Xiaolei and Ruruku, Tyrone Te},
  title = {Assessing the sensitivity and suitability of a range of detectors for SIMT PSQA},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14343}
}
Kostenlos starten →