A novel ‘stop-hole’ strategy to extend the fatigue life of orthodontic thermoformed retainers: an in vitro study
European Journal of Orthodontics · 01.12.2024 · 46 (6)
DOI: 10.1093/ejo/cjae061 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthodontics, online erschienen am 11.11.2024. Verfasst von Jae Sik Son und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, UCL Eastman Dental Institute, University College London, Rockefeller Building, 21 University Street, London WC1E 6DE, Uni…. Hauptthemen laut MEDLINE: Materials Testing, Orthodontic Retainers, Orthodontic Appliance Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
This study aimed to investigate the potential to limit crack propagation in thermoformed retainers (TRs) and extend their fatigue life by placing a ‘stop-hole’.
Methods
Thirty-two TRs, fabricated from 1 mm thick, round polyethylene terephthalate glycol (PETG) blanks of ICONIC®, underwent testing within a custom-built fatigue tester. After initial crack growth of 3 mm, the TRs were divided into three groups: a control group (C) and two experimental groups based on the stop-hole placement method. In the first experimental group, stop-holes were placed using a 1 mm round carbide bur on a slow-speed handpiece (ES), while the second group utilized a heated 1-mm-width ball-ended CPITN probe (EH). Following the placement of a stop-hole at the crack-tip, all 32 TRs resumed testing until the final crack length of 10 mm was reached.
Results
Stop-hole placement significantly prolonged the delay in crack re-initiation in both experimental groups compared to the control group (P < .001 for both). The mean re-initiation times for the ES and EH groups were 104.50 and 129.50 min, respectively, whereas the control group was 28.94 min. Consequently, this discrepancy was reflected in the total testing times, with both experimental groups requiring significantly longer time to reach the final crack length (P < .001). There was no significant difference in the testing times between the two experimental groups.
Limitations
This is an in vitro study.
Conclusions
The stop-hole methodology significantly extended the fatigue life of a TR in a controlled laboratory environment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthodontics, UCL Eastman Dental Institute, University College London, Rockefeller Building, 21 University Street, London WC1E 6DE, United Kingdom.
- Department of Mechanical Engineering, Faculty of Engineering Sciences, University College London, Roberts Engineering Building, Torrington Place, London WC1E 7JE, United Kingdom.
ORCID-Profile: Jae Sik Son
Zitieren
APA
Son, J. S., Wojcik, A., & Noar, J. (2024). A novel ‘stop-hole’ strategy to extend the fatigue life of orthodontic thermoformed retainers: an in vitro study. European Journal of Orthodontics, 46(6). https://doi.org/10.1093/ejo/cjae061
Vancouver
Son JS, Wojcik A, Noar J. A novel ‘stop-hole’ strategy to extend the fatigue life of orthodontic thermoformed retainers: an in vitro study. European Journal of Orthodontics. 2024;46(6). doi:10.1093/ejo/cjae061
BibTeX
@article{Son2024,
author = {Son, Jae Sik and Wojcik, Adam and Noar, Joseph},
title = {A novel ‘stop-hole’ strategy to extend the fatigue life of orthodontic thermoformed retainers: an in vitro study},
journal = {European Journal of Orthodontics},
year = {2024},
volume = {46},
number = {6},
doi = {10.1093/ejo/cjae061}
}
EUVIMED