Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study
Lasers in Medical Science · 2025
DOI: 10.1007/s10103-025-04348-4 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Lasers in Medical Science, 2025. Verfasst von Merve Kurnaz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Istanbul Kent University, Istanbul, Turkey. mervekurnaz92@gmail.com. Hauptthemen laut MEDLINE: Orthodontic Retainers. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Istanbul Kent University.
Abstract (Originalsprache)
This study aims to assess the in vitro durability of Nitinol retainers, manufactured using computer-aided methods with hydrophilic or superhydrophilic surfaces to reduce debonding, alongside a commonly used composite adhesive. The 112 lower incisor teeth were embedded in blocks in pairs. Retainer wires were made up of 0.018 × 0.018 inch Nickel Titanium alloy(G4™ Nickel Titanium G&H Orthodontics, USA) by bending a robot arm. A total of 16 teeth(8 blocks) were used for each of the mentioned 7 groups Ni-Ti Retainer; Laser Textured Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer; Atmospheric Plasma Applicated Ni-Ti Retainer; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*2; Laser Texturing and Atmospheric Plasma Applicated Ni-Ti Retainer*3; SS-0.0018“(Morelli, Brazil). Transbond LR(3 M Unitek, California) was used. The shear bond strength tests were conducted. The Kruskal-Wallis H test was employed, pairwise comparisons followed by Dunn’s test with Bonferroni correction as a post-hoc analysis. There was no statistically significant difference between the groups for maximum force and maximum stress(p > 0.05). However, a significant difference was found in maximum elongation (p:0.0023). Pairwise comparisons highlighted significantly higher elongation values in the SS-0.0018” group. The stainless-steel wire demonstrated higher elongation values, which may offer clinical advantages in cases with higher occlusal forces and periodontal problems due to its material flexibility. Laser Texturing and Atmospheric Plasma Applied Ni-Ti Retainers exhibited higher test performance. Surface treatments applied to CAD/CAM retainers can provide an advantage by enhancing bond strength, potentially reducing the risk of debonding. These findings underline the importance of material selection and surface treatments in optimizing fixed retention strategies for long-term clinical success.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Istanbul Kent University, Istanbul, Turkey. mervekurnaz92@gmail.com.
- Private Company Permatter LLC, Florida, USA.
- Gelişim Üniversitesi, Istanbul, Turkey.
Förderung
- Istanbul Kent University
Zitieren
APA
Kurnaz, M., Nazan, A. A., & Eraydın, F. (2025). Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study. Lasers in Medical Science. https://doi.org/10.1007/s10103-025-04348-4
Vancouver
Kurnaz M, Nazan AA, Eraydın F. Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study. Lasers in Medical Science. 2025. doi:10.1007/s10103-025-04348-4
BibTeX
@article{Kurnaz2025,
author = {Kurnaz, Merve and Nazan, Ali Arslan and Eraydın, Feyza},
title = {Comparative evaluation of the performance of orthodontic retainers using different surface protocols: an in vitro study},
journal = {Lasers in Medical Science},
year = {2025},
doi = {10.1007/s10103-025-04348-4}
}
EUVIMED