Wear and fatigue resistance: An in-vitro comparison of three polyethylene terephthalate glycol and thermoplastic polyurethane materials for vacuum-formed retainers
International Orthodontics · 2023-06 · 21 (2) · 100748
DOI: 10.1016/j.ortho.2023.100748 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Orthodontics, 2023-06. Verfasst von Thorsten Grünheid und 1 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthodontics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA. Electronic address: tgruenhe@umn.edu. Hauptthemen laut MEDLINE: Polyurethanes, Orthodontic Retainers. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: To test the wear and fatigue resistance of three materials (Essix ACE®, Taglus®, and Zendura A®) for the fabrication of vacuum-formed retainers in an artificial oral environment. MATERIAL AND METHODS: Wear resistance was tested by subjecting 21 retainers of each Essix ACE®, Taglus®, and Zendura A® to 12,000 wear cycles at 75N to simulate one year of retainer wear with moderate nighttime bruxing. Post-wear retainer thickness was compared to baseline measurements to calculate wear depth. Fatigue resistance was tested by flexing 15 retainers of each material at an angle of 25 degrees for 1,825 cycles to simulate one year of removing and reinserting a retainer five times per day. Retainers were visually inspected for fractures. Pairwise t-tests with correction using Tukey's method were used to determine significant differences between materials. RESULTS: The mean wear depths were 0.155±0.021mm, 0.168±0.031mm, and 0.096±0.033mm for Essix ACE®, Taglus®, and Zendura A®, respectively. The wear depth of Zendura A® was significantly lower than that of both Essix ACE® (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Orthodontics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA. Electronic address: tgruenhe@umn.edu.
- Private Practice, Brigham City, Utah, USA.
Zitieren
APA
Grünheid, T., & Bitner, T. F. (2023). Wear and fatigue resistance: An in-vitro comparison of three polyethylene terephthalate glycol and thermoplastic polyurethane materials for vacuum-formed retainers. International Orthodontics, 21(2), 100748. https://doi.org/10.1016/j.ortho.2023.100748
Vancouver
Grünheid T, Bitner TF. Wear and fatigue resistance: An in-vitro comparison of three polyethylene terephthalate glycol and thermoplastic polyurethane materials for vacuum-formed retainers. International Orthodontics. 2023;21(2):100748. doi:10.1016/j.ortho.2023.100748
BibTeX
@article{Grnheid2023,
author = {Grünheid, Thorsten and Bitner, Timothy F},
title = {Wear and fatigue resistance: An in-vitro comparison of three polyethylene terephthalate glycol and thermoplastic polyurethane materials for vacuum-formed retainers},
journal = {International Orthodontics},
year = {2023},
volume = {21},
number = {2},
pages = {100748},
doi = {10.1016/j.ortho.2023.100748}
}
EUVIMED