EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods

Kalliopi Siotou, Theofanis Chountalas, Athanasios Katsavrias, Charalampos Siotos, Konstantinos Mpalias, Dionysios Semitekolos, Constantinos Charitidis, Apostolos I Tsolakis

Orthodontics & Craniofacial Research · 2024

DOI: 10.1111/ocr.12867 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthodontics & Craniofacial Research, 2024. Verfasst von Kalliopi Siotou und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, National and Kapodistrian University of Athens, Athens, Greece. Hauptthemen laut MEDLINE: Orthodontic Appliances, Removable, Orthodontic Appliance Design. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Although the technique of orthodontic aligners has risen in popularity, their mechanical properties have not been thoroughly investigated. The aim of this study was to evaluate the mechanical properties of the orthodontic aligners Clear Aligner after intraoral use for 7, 10 and 14 days, and to compare them with as‐received aligners (0 days). It was also sought to examine the properties of the unprocessed raw material (polyethylene glycol terephthalate) used to manufacture these aligners. Materials/Methods Thirty‐two aligners by four patients were evaluated and studied at 0, 7, 10, 14 days of use. Each aligner was divided into three segments (two posterior and one anterior), which resulted in 96 samples. Also, 16 samples of unprocessed material were studied. For all samples, elastic modulus, ultimate tensile stress (UTS) and yield stress were calculated by conducting tensile testing. Additionally, material hardness was tested. The two‐tailed Mann–Whitney test was performed, having set the level of significance at p = 0.05.

Results

Analysis of the measurements indicated a statistically significant decrease in elastic modulus between days 0 and 14 of use, of UTS between days 0 and 7, 7 and 10, and of yield stress between days 0 and 7. For hardness, in every period, posterior segments demonstrated significantly higher values than anterior segments. All properties of the unprocessed material were statistically significantly higher than the processed samples.

Conclusions

The unprocessed material presented significant differences in every property tested in comparison to the processed aligners. The processed material showed further deterioration over time during use. The present study provides evidence that thermoforming and ageing affect the mechanical properties of the aligners.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic Appliances, RemovableOrthodontic Appliance DesignHumansElastic ModulusTensile StrengthTime FactorsMaterials TestingStress, MechanicalHardnessPolyethylene GlycolsDental Stress AnalysisPolyethylene TerephthalatesMale

Stichwörter der Autor:innen

ageingclear alignerintraoralmechanical propertiesorthodontic aligners

Substanzen

polyethylene terephthalate glycolPolyethylene GlycolsPolyethylene Terephthalates

Autor:innen und Institutionen

  • Department of Orthodontics, National and Kapodistrian University of Athens, Athens, Greece.
  • Department of Laboratory of Heterogeneous Mixtures & Combustion Systems, Mechanical Engineering School of the National Technical University of Athens, Athens, Greece.
  • Research Lab of Advanced, Composite, Nano Materials & Nanotechnology, Chemical Engineering School of the National Technical University of Athens, Zografou, Greece.
  • Division of Plastic and Reconstructive Surgery, Rush University Medical Center, Chicago, Illinois, USA.

Zitieren

APA

Siotou, K., Chountalas, T., Katsavrias, A., Siotos, C., Mpalias, K., Semitekolos, D., Charitidis, C., & Tsolakis, A. I. (2024). The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12867

Vancouver

Siotou K, Chountalas T, Katsavrias A, Siotos C, Mpalias K, Semitekolos D, et al. The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12867

BibTeX
@article{Siotou2024,
  author = {Siotou, Kalliopi and Chountalas, Theofanis and Katsavrias, Athanasios and Siotos, Charalampos and Mpalias, Konstantinos and Semitekolos, Dionysios and Charitidis, Constantinos and Tsolakis, Apostolos I},
  title = {The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods},
  journal = {Orthodontics & Craniofacial Research},
  year = {2024},
  doi = {10.1111/ocr.12867}
}
Kostenlos starten →