Cleaning of photostimulable phosphor plates with chlorhexidine-based substances does not affect image quality of radiographs
Dentomaxillofacial Radiology · 01.05.2026 · 55 (4) · 362-369
DOI: 10.1093/dmfr/twag004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, online erschienen am 14.01.2026. Verfasst von Carolina Paes Borge und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba 13414-903, SP, Brazil. Hauptthemen laut MEDLINE: Chlorhexidine, Radiography, Dental, Digital, X-Ray Intensifying Screens. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Objectives
To evaluate image quality of radiographs obtained with photostimulable phosphor (PSP) plates after cleaning with 2% chlorhexidine.
Methods
Eight PSP plates were used: 4 from Express system and 4 from VistaScan system. Two plates from each system were wiped with 2% chlorhexidine in aqueous solution (CHX AQ), and the other 2 plates from each system with 2% chlorhexidine in alcoholic solution (CHX AL). Before cleaning and after every 5 cleaning cycles (up to 100 cleanings), 2 radiographs of an acrylic block and 2 of an aluminium step wedge were acquired with each PSP plate. The image’s gray values were measured to assess image brightness, noise, uniformity, and contrast. Two-way repeated measures ANOVA followed by Sidak’s post hoc test analysed the influence of the number of cleanings and substance type on these parameters (α = 0.05).
Results
Considering the number of cleanings, image brightness varied for CHX AL in the Express system and CHX AQ in the VistaScan system, with no consistent pattern (P < .05). Noise varied for both substances in the VistaScan system, also without a clear pattern (P < .05). In the Express system, regarding the substance type, CHX AL resulted in lower brightness and CHX AQ in lower noise after 75 cleanings (P < .05). Contrast and uniformity were not affected by either the number of cleanings or the substance type (P > .05). Despite numerical variations in some objective parameters, overall image quality remained stable across all cleanings for both substances. No artefacts were observed in the images.
Conclusion
Regarding image quality, 2% chlorhexidine—whether aqueous or alcohol-based—can be recommended for PSP plates cleaning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba 13414-903, SP, Brazil.
ORCID-Profile: Carolina Paes Borge, Iago Filipe Correia-Dantas, Débora Costa Ruiz, Thamiles Gonzalez-Passos, Deborah Queiroz Freitas, Amanda Farias-Gomes
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Borge, C. P., Correia-Dantas, I. F., Ruiz, D. C., Gonzalez-Passos, T., Freitas, D. Q., & Farias-Gomes, A. (2026). Cleaning of photostimulable phosphor plates with chlorhexidine-based substances does not affect image quality of radiographs. Dentomaxillofacial Radiology, 55(4), 362-369. https://doi.org/10.1093/dmfr/twag004
Vancouver
Borge CP, Correia-Dantas IF, Ruiz DC, Gonzalez-Passos T, Freitas DQ, Farias-Gomes A. Cleaning of photostimulable phosphor plates with chlorhexidine-based substances does not affect image quality of radiographs. Dentomaxillofacial Radiology. 2026;55(4):362-369. doi:10.1093/dmfr/twag004
BibTeX
@article{Borge2026,
author = {Borge, Carolina Paes and Correia-Dantas, Iago Filipe and Ruiz, Débora Costa and Gonzalez-Passos, Thamiles and Freitas, Deborah Queiroz and Farias-Gomes, Amanda},
title = {Cleaning of photostimulable phosphor plates with chlorhexidine-based substances does not affect image quality of radiographs},
journal = {Dentomaxillofacial Radiology},
year = {2026},
volume = {55},
number = {4},
pages = {362--369},
doi = {10.1093/dmfr/twag004}
}
EUVIMED