A review of radiotherapy linear accelerator quality control techniques
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag162 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Elisha Tassano-Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom. Hauptthemen laut MEDLINE: Particle Accelerators, Quality Control, Quality Assurance, Health Care, Radiotherapy. Die Arbeit nennt 116 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
This study provides a review of recent publications on different quality control (QC) techniques for radiotherapy linear accelerators (linacs). QC in radiotherapy is essential to ensure patient safety, deliver optimal quality treatments, monitor equipment performance over time, and to satisfy statutory or recommended testing. While conventional QC methods are still widely used and valuable, there have been advances in QC methods and approaches which aim to improve efficiency and keep pace with the rapidly advancing complexity of clinical equipment and treatment delivery methods. Existing reviews of QC concepts mainly focus on single QC techniques. There are limited reviews that explore and compare the variety of techniques to QC, which is the aim of this report. QC techniques were separated into 7 domains: conventional QC, automated and manufacturer integrated QC, risk, statistical, artificial intelligence (AI), end-to-end and patient-specific QC (PSQC), external dosimetry audits and clinical trial credentialing audits. An overview of each technique with example studies from literature is presented.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom.
- Medical Physics Department, Portsmouth Hospitals University NHS Trust, Queen Alexandra Hospital, Portsmouth, Hampshire PO6 3LY, United Kingdom.
ORCID-Profile: Elisha Tassano-Smith, Antony L Palmer, Wojciech Polak, Andrew Nisbet
Zitieren
APA
Tassano-Smith, E., Palmer, A. L., Polak, W., & Nisbet, A. (2026). A review of radiotherapy linear accelerator quality control techniques. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag162
Vancouver
Tassano-Smith E, Palmer AL, Polak W, Nisbet A. A review of radiotherapy linear accelerator quality control techniques. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag162
BibTeX
@article{TassanoSmith2026,
author = {Tassano-Smith, Elisha and Palmer, Antony L and Polak, Wojciech and Nisbet, Andrew},
title = {A review of radiotherapy linear accelerator quality control techniques},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag162}
}
EUVIMED