Evaluation of patient-specific quality assurance for fractionated stereotactic treatment plans with 6 and 10MV photon beams in beam-matched linacs
Radiological Physics and Technology · 2024
DOI: 10.1007/s12194-024-00848-0 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Mageshraja Kannan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India. mageshraja.k@gmail.com. Hauptthemen laut MEDLINE: Photons, Particle Accelerators, Radiotherapy Planning, Computer-Assisted, Quality Assurance, Health Care. Die Arbeit nennt 35 Literaturangaben.
Abstract (Originalsprache)
Beam-matched linear accelerators (LA's) require accurate and precise dosimetry for fractionated stereotactic treatment. In this study, the beam data were validated by comparing the three-beam-matched LA's measured data and the vendor reference data. Upon its validation, the accuracy of the volumetric dose delivery for eighty patient-specific fractionated stereotactic treatment plans was evaluated. Measurements of the percentage depth dose (PDD), beam profiles, output factors (OFs), absolute output, and dynamic multi-leaf collimator (MLC) transmission factors for 6 MV and 10 MV flattening filter (FF) and flattening filter-free (FFF) photon beams were obtained from three-beam-matched LA's. The patient-specific quality assurance evaluation for all eighty plans was performed using PTW Octavius 1000 SRS™ array detectors for two-dimensional (2D) fluence measurement. The following 2D gamma passing criteria were used: 1%/1 mm, 2%/1 mm, 1%/2 mm, 2%/2 mm and 3%/2 mm. In all three LA's, gamma analysis for PDD and profile were above 97% with gamma criteria of 1%/1 mm. The differences OFs, absolute output, and dynamic MLC transmission factors were less than ± 1% of base value. For all eighty cases, the median passing rates on the three LA's were above 76%, 88%, 92%, 96%, and 98% for the above-mentioned gamma criteria of the three LA's. The beam-matched LA's showed good agreement between the measured and treatment planning system (TPS) calculated values for fractionated stereotactic VMAT plans with 6 MV and 10 MV (FF and FFF) photon beams. Patients can be shifted and treated on any beam-matched linac without the need of re-planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India. mageshraja.k@gmail.com.
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.
Zitieren
APA
Kannan, M., Saminathan, S., Chandraraj, V., Shwetha, B., Gowtham Raj, D., & Ganesh, K. M. (2024). Evaluation of patient-specific quality assurance for fractionated stereotactic treatment plans with 6 and 10MV photon beams in beam-matched linacs. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00848-0
Vancouver
Kannan M, Saminathan S, Chandraraj V, Shwetha B, Gowtham Raj D, Ganesh KM. Evaluation of patient-specific quality assurance for fractionated stereotactic treatment plans with 6 and 10MV photon beams in beam-matched linacs. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00848-0
BibTeX
@article{Kannan2024,
author = {Kannan, Mageshraja and Saminathan, Sathiyan and Chandraraj, Varatharaj and Shwetha, B and Gowtham Raj, D and Ganesh, K M},
title = {Evaluation of patient-specific quality assurance for fractionated stereotactic treatment plans with 6 and 10MV photon beams in beam-matched linacs},
journal = {Radiological Physics and Technology},
year = {2024},
doi = {10.1007/s12194-024-00848-0}
}
EUVIMED