EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Automated contouring and radiotherapy treatment planning of spine metastases using atlas-based auto-segmentation and knowledge-based planning approaches

Emma-Louise Jones, Porsher Oppong, Caroline Sisodia, Carolina Napoleone-Filho, Victoria Harris, Christopher Golby, David Eaton iD, Antony Greener

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqaf041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Emma-Louise Jones und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Clinical Engineering, Guy's and St Thomas' NHS Foundation Trust, St Thomas' Hospital, London SE1 7EH, United Kingdo…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Spinal Neoplasms. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Varian Medical Systems, University of Manchester, Health Education England.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Spine metastases are routinely treated with conventional external beam radiotherapy (cEBRT) where there is no delineation of target volumes (TV) or organs at risk (OAR), or attempt to optimize dose distribution. Automated contouring and treatment planning could facilitate conformal planning of spine metastases in the clinical environment.

Methods

Atlas-based auto-segmentation (ABAS) using SmartSegmentation was developed for delineation of thoracic and lumbar vertebrae, and OAR; knowledge-based planning (KBP) using RapidPlan was developed for conformal volumetric-modulated arc therapy treatment planning. Plans produced using this automated approach were compared to the equivalent cEBRT plans.

Results

TV coverage for automated ABAS/KBP conformal treatment plans were superior to cEBRT. The planning target volume (PTV) Dmean = 7.86 ± 0.16 Gy, Dmin = 3.46 ± 1.79 Gy, Dmax = 8.56 ± 0.05 Gy compared to PTV Dmean = 7.78 ± 0.24 Gy, Dmin = 1.83 ± 1.08 Gy, Dmax = 10.46 ± 0.41 Gy, with homogeneity index and conformity index 0.236 ± 0.215 and 1.201 ± 0.121, respectively, for ABAS/KBP compared to 0.508 ± 0.137 and 1.789 ± 0.437 for cEBRT. Dose to dose-limiting spinal cord and cauda equina was reduced in ABAS/KBP plans, with Dmax of 7.91 ± 0.16 Gy and 7.94 ± 0.13 Gy, respectively, compared to 8.67 ± 0.13 Gy and 8.90 ± 0.16 Gy for cEBRT.

Conclusions

Automated conformal treatment planning was achievable, with improved sparing of dose-limiting OAR and superior plan quality compared to cEBRT. Automation of the planning process makes this feasible for implementation in the clinical environment. Advances in knowledge Automated contouring and treatment planning are feasible in the clinical environment using this approach. We describe the first use of ABAS and KBP for radiotherapy treatment of spine metastases that would allow patients to receive conformal as opposed to the widely used approach of cEBRT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedSpinal NeoplasmsHumansRadiotherapy DosageOrgans at RiskRadiotherapy, Intensity-ModulatedThoracic VertebraeLumbar VertebraeKnowledge BasesTomography, X-Ray Computed

Stichwörter der Autor:innen

RapidPlanatlas-based auto-segmentationautomationknowledge-based planningspine metastases

Autor:innen und Institutionen

  • Department of Medical Physics and Clinical Engineering, Guy's and St Thomas' NHS Foundation Trust, St Thomas' Hospital, London SE1 7EH, United Kingdom.
  • Department of Clinical Haematology and Oncology, Guy's and St Thomas' NHS Foundation Trust, Guy's Cancer Centre, Guy's Hospital, London SE1, 9RT, United Kingdom.
  • Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester M20 4BX, United Kingdom.
  • School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, Kings College London, Strand, London, WC2R 2LS, United Kingdom.

ORCID-Profile: David Eaton

Förderung

  • Varian Medical Systems
  • University of Manchester
  • Health Education England
  • Higher Specialist Scientist Training

Zitieren

APA

Jones, E. L., Oppong, P., Sisodia, C., Napoleone-Filho, C., Harris, V., Golby, C., Eaton, D., & Greener, A. (2025). Automated contouring and radiotherapy treatment planning of spine metastases using atlas-based auto-segmentation and knowledge-based planning approaches. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf041

Vancouver

Jones EL, Oppong P, Sisodia C, Napoleone-Filho C, Harris V, Golby C, et al. Automated contouring and radiotherapy treatment planning of spine metastases using atlas-based auto-segmentation and knowledge-based planning approaches. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf041

BibTeX
@article{Jones2025,
  author = {Jones, Emma-Louise and Oppong, Porsher and Sisodia, Caroline and Napoleone-Filho, Carolina and Harris, Victoria and Golby, Christopher and Eaton, David and Greener, Antony},
  title = {Automated contouring and radiotherapy treatment planning of spine metastases using atlas-based auto-segmentation and knowledge-based planning approaches},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqaf041}
}
Kostenlos starten →