Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Kemal Berk und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Patient‐specific quality assurance (PSQA) for vertebra stereotactic body radiation therapy (SBRT) presents challenges due to highly modulated small fields with high‐dose gradients between the target and spinal cord. This study aims to explore the use of the SRS MapCHECK® (SRSMC) for vertebra SBRT PSQA.

Methods

Twenty vertebra SBRT treatment plans including prescriptions 20 Gy/1 fraction and 24 Gy/2 fractions were selected for each of Millennium (M)‐Multileaf Collimator (MLC), and high‐definition (HD)‐MLC. All 40 plans were measured using Gafchromic EBT3 film (film) and SRSMC, using the StereoPHAN phantom. Plan complexity was assessed using modulation complexity score (MCS), edge metric (EM) (mm −1 ), modulation factor (MU/cGy), and average leaf pair opening (ALPO) (mm) and its correlation with gamma‐pass rate was investigated. The high dose gradient between the target and the spinal cord was analyzed for film and SRSMC and compared against the treatment planning system (TPS). Applying the methodology proposed by AAPM TG‐218, action and tolerance values specific to the SRSMC for vertebra SBRT were determined for β values ranging from 5 to 8.

Results

Film and SRSMC gamma‐pass rates showed no correlation ( p > 0.05). A moderate negative correlation ( R = ‐0.57, p = 0.01) is present between EM and SRSMC 3%/1 mm gamma‐pass rate for HD‐MLC plans. Both film and SRSMC accurately measured high dose gradients between the target and the spinal cord ( R 2 > 0.86, p ≤ 0.05). Notably, dose‐gradient of HD‐MLC plans is 22% steeper and has a smaller standard deviation to M‐MLC plans ( p ≤ 0.05). Applying TG‐218, the film tolerance limit was 96% with action limit 95% for 5%/1 mm (β = 6) and for the SRSMC tolerance limit was 97% with an action limit of 96% for 4%/1 mm (β = 6).

Conclusion

Our findings suggest that universal TG‐218 limits may not be suitable for vertebra SBRT PSQA. This study demonstrates that SRSMC is a viable tool for vertebra SBRT PSQA, supported by TG‐218 implementation of process‐based tolerance and action limits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedRadiotherapy DosageRadiotherapy, Intensity-ModulatedQuality Assurance, Health CareOrgans at RiskPhantoms, ImagingHumansSpinal Neoplasms

Stichwörter der Autor:innen

SRS MapCHECKTG‐218patient‐specific quality assurance (PSQA)vertebra SBRT

Autor:innen und Institutionen

  • Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Sir Peter MacCallum Department of Oncology, the University of Melbourne, Melbourne, Victoria, Australia.
  • Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.

ORCID-Profile: Adam Unjin Yeo

Zitieren

APA

Berk, K., Kron, T., Hardcastle, N., & Yeo, A. U. (2024). Efficacious patient‐specific QA for Vertebra SBRT using a high‐resolution detector array SRS MapCHECK: AAPM TG‐218 analysis. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14276

Vancouver

Berk K, Kron T, Hardcastle N, Yeo AU. Efficacious patient‐specific QA for Vertebra SBRT using a high‐resolution detector array SRS MapCHECK: AAPM TG‐218 analysis. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14276

BibTeX
@article{Berk2024,
  author = {Berk, Kemal and Kron, Tomas and Hardcastle, Nicholas and Yeo, Adam Unjin},
  title = {Efficacious patient‐specific QA for Vertebra SBRT using a high‐resolution detector array SRS MapCHECK: AAPM TG‐218 analysis},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14276}
}
Kostenlos starten →