EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study

Hiroyuki Okamoto iD, Midori Nonaka, Takahito Chiba iD, Tomoya Kaneda, Yuta Kobayashi, Satoshi Nakamura, Hiroki Nakayama, Kotaro Iijima, Yasunori Shuto, Miki Yonemura, Riki Oshika, Hironori Kishida und 7 weitere

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14403 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Hiroyuki Okamoto und 18 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Spinal Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Cancer Center Research and Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam‐off at specific gantry angles).

Methods

A total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference ( DD) and relative value ( DD %) were evaluated using the dose‐volume histogram (DVH) metrics, planning target volume D max , D 95% , spinal cord D 0.035 cc , and esophagus D 2.5 cc . The magnitude of the liver movements was evaluated based on differences of liver size L ave at the isocentric axial plane between the inspiratory and expiratory CT images.

Results

The DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean a standard deviation (SD) DD in PTV D 95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 0.3 and 0.9 0.6 Gy, respectively. The spinal cord D 0.035 cc for those shows 0.4 0.2 and 0.7 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between L ave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D 0.035 cc revealed approximately 1 Gy or +4% in DD when L ave was < −4 cm.

Conclusions

Respiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath‐hold. Alternatively, beam avoidance effectively mitigates the impact.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedRadiotherapy DosageSpinal NeoplasmsRadiotherapy, Intensity-ModulatedLiverOrgans at RiskRespirationHumansRetrospective StudiesMaleFemaleAgedMiddle AgedMovementTomography, X-Ray ComputedPrognosisAged, 80 and over

Stichwörter der Autor:innen

SBRTdosimetric impactspine metastasis

Autor:innen und Institutionen

  • Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Department of Radiological Technology, National Cancer Center Hospital, Tokyo, Japan.
  • Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Department of Radiation Oncology, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan.
  • Department of Radiological Sciences, Komazawa University Graduate School, Tokyo, Japan.

ORCID-Profile: Hiroyuki Okamoto, Takahito Chiba

Förderung

  • National Cancer Center Research and Development Fund

Zitieren

APA

Okamoto, H., Nonaka, M., Chiba, T., Kaneda, T., Kobayashi, Y., Nakamura, S., Nakayama, H., Iijima, K., Shuto, Y., Yonemura, M., Oshika, R., Kishida, H., Urago, Y., Nishitani, M., Nishina, S., Sakamoto, T., Shibata, Y., Goka, T., & Igaki, H. (2024). Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14403

Vancouver

Okamoto H, Nonaka M, Chiba T, Kaneda T, Kobayashi Y, Nakamura S, et al. Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14403

BibTeX
@article{Okamoto2024,
  author = {Okamoto, Hiroyuki and Nonaka, Midori and Chiba, Takahito and Kaneda, Tomoya and Kobayashi, Yuta and Nakamura, Satoshi and Nakayama, Hiroki and Iijima, Kotaro and Shuto, Yasunori and Yonemura, Miki and Oshika, Riki and Kishida, Hironori and Urago, Yuka and Nishitani, Masato and Nishina, Shuka and Sakamoto, Takumi and Shibata, Yoshihiro and Goka, Tomonori and Igaki, Hiroshi},
  title = {Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14403}
}
Kostenlos starten →