In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser
Journal of Endourology · 2024-12 · 38 (12) · 1427-1435
DOI: 10.1089/end.2024.0424 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Endourology, online erschienen am 01.12.2024. Verfasst von Marie Chicaud und 9 weiteren Autor:innen. Beteiligte Einrichtung: GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, Paris, France. Hauptthemen laut MEDLINE: Thulium, Lasers, Solid-State. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Objective: To characterize the pulse characteristics and risk of fiber fracture (ROF) of the pulsed-Thulium:YAG (p-Tm:YAG) laser and to compare its ablation volumes (AVs) against Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) laser and Thulium fiber laser (TFL). Materials and Methods: p-Tm:YAG (100 W-Thulio, Dornier-Medtech © , Germany) was characterized using single-use 272 μm core-diameter-fibers. p-Tm:YAG characterization included pulse shape, duration, and peak power (PP) studies. ROF was assessed after 5 minutes of continuous laser activation (CLA) at five decreasing fiber bend radii (1, 0.9, 0.75, 0.6, and 0.45 cm). p-Tm:YAG, Ho:YAG (120 W-Cyber-Ho, Quanta ® , USA), and TFL (60 W-TFLDrive, Coloplast ® , Denmark) AVs were compared using a 20-mm linear CLA at 2 mm/second velocity in contact with 20 mm 3 hard stone phantoms (HSP) and soft stone phantoms (SSP) (15:3 and 15:5 water to powder ratio, respectively) fully submerged in saline at 0.5 J–20 Hz or 1 J–10 Hz. After CLA, phantoms underwent three-dimensional (3D) micro-scanning (CT) and subsequent 3D segmentation to estimate the AVs, using 3DSlicer © . Each experiment was performed in triplicate. Results: p-Tm:YAG presents a uniform pulse profile in all of the available preset modes. PP ranged from 564 to 2199 W depending on pulse mode. No laser fiber fracture occurred at any bend radius. p-Tm:YAG achieved similar mean AVs to TFL and Ho:YAG for HSP (8.96 ± 3.1 vs 9.78 ± 1.1 vs 8.8 ± 2.8 mm 3 , p = 0.67) but TFL was associated with higher AVs compared with p-Tm:YAG and Ho:YAG (12.86 ± 1.85 vs 10.12 ± 1.89 vs 7.56 ± 2.21 mm 3 , p = 0.002) against SSP. AVs for HSP increased with pulse energy for p-Tm:YAG and Ho:YAG and (11.56 ± 1.8 vs 6.36 ± 0.84 mm 3 and 11.27 ± 1.98 vs 6.34 ± 0.55 mm 3 , p = 0.03 and p = 0.02), whereas AVs for SSP were similar across laser settings for all laser sources. AVs with TFL were similar across laser settings for both phantom types. Conclusion: p-Tm:YAG combines intermediate PP between Ho:YAG and TFL, a uniform pulse profile, no ROF with increasing deflection and effective ablation rates. Further clinical studies are needed to confirm these in vitro results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, Paris, France.
- Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, Paris, France.
- PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, 151 bd de l'Hôpital, Paris, France.
- Service d'Urologie, CHU Limoges, Limoges, France.
- Department of Urology, Poitiers University Hospital, Poitiers, France.
- Progressive Endourological Association for Research and Leading Solutions (PEARLS), Paris, France.
ORCID-Profile: Mariela Corrales
Zitieren
APA
Chicaud, M., Kutchukian, S., Berthe, L., Corrales, M., Solano, C., Candela, L., Doizi, S., Smith, D., Traxer, O., & Panthier, F. (2024). In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser. Journal of Endourology, 38(12), 1427-1435. https://doi.org/10.1089/end.2024.0424
Vancouver
Chicaud M, Kutchukian S, Berthe L, Corrales M, Solano C, Candela L, et al. In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser. Journal of Endourology. 2024;38(12):1427-1435. doi:10.1089/end.2024.0424
BibTeX
@article{Chicaud2024,
author = {Chicaud, Marie and Kutchukian, Stessy and Berthe, Laurent and Corrales, Mariela and Solano, Catalina and Candela, Luigi and Doizi, Steeve and Smith, Daron and Traxer, Olivier and Panthier, Frédéric},
title = {In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser},
journal = {Journal of Endourology},
year = {2024},
volume = {38},
number = {12},
pages = {1427--1435},
doi = {10.1089/end.2024.0424}
}
EUVIMED