Feasibility of canine minibeam radiotherapy (MBRT) with a dual-robot kilovoltage x-ray system
Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215013
DOI: 10.1088/1361-6560/aeb8dd ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 03.11.2026. Verfasst von Laura Dufort-Gagnon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Physics and Astronomy, University of Victoria, Victoria, Canada. Hauptthemen laut MEDLINE: Robotics. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Nature et technologies.
Abstract (Originalsprache)
Objective. To evaluate the feasibility of delivering minibeam radiotherapy (MBRT) to a canine glioblastoma patient using a novel low-cost dual-robot kilovoltage (kV) x-ray system. Approach. A workflow to perform MBRT using a tungsten collimator with 300 μ m slits was developed for the 225 kVp x-ray source system. A Monte Carlo (MC) model of MBRT was built in TOPAS and validated with EBT4 measurements in-air and in a solid water phantom. A non-coplanar MBRT treatment plan with 2 mm Al- and 0.5 mm Cu-filtered beams was created for the canine patient and compared to a clinical 6 MV VMAT plan. A full set and individual minibeam fields were delivered to a canine head phantom with an intracranial film to verify plan feasibility. Main results. Measured and MC-simulated peak-to-valley dose ratios in-air and in the water phantom agreed within ⩽ 2 σ . Open-beam and collimated peak dose measurements at depths acquired with films in the water phantom agreed with simulations with mean relative differences of 1% and 2%, respectively. MBRT treatment plan spatial fractionation was preserved in healthy tissue for tissue-sparing benefits. Mean MBRT doses to organs at risk were within 15% of VMAT, except for skin (+52% for Al- and +48% for Cu-filtered beams), bone (+28% for Al and +22% for Cu) and the right ear (–39% for Al and –42% for Cu). Dose difference map average in the canine head phantom was 2.3 ± 1.2% for one and 3.5 ± 2.2% for two minibeam fields. Significance. These results demonstrate the feasibility of MBRT delivery using the novel x-ray system to a canine due to spatial fractionation and adequate depth dose delivered to the tumor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physics and Astronomy, University of Victoria, Victoria, Canada.
- Computer Science, University of Victoria, Victoria, Canada.
- Dunlee, brand of Philips, Best, The Netherlands.
ORCID-Profile: Laura Dufort-Gagnon, Jade Fischer, Joshua Chapman, Olivia Masella, Nicola Carbone, Magdalena Bazalova-Carter
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Nature et technologies
Zitieren
APA
Dufort-Gagnon, L., Fischer, J., Chapman, J., Stewart, L., Masella, O., Carbone, N., & Bazalova-Carter, M. (2026). Feasibility of canine minibeam radiotherapy (MBRT) with a dual-robot kilovoltage x-ray system. Physics in Medicine & Biology, 71(21), 215013. https://doi.org/10.1088/1361-6560/aeb8dd
Vancouver
Dufort-Gagnon L, Fischer J, Chapman J, Stewart L, Masella O, Carbone N, et al. Feasibility of canine minibeam radiotherapy (MBRT) with a dual-robot kilovoltage x-ray system. Physics in Medicine & Biology. 2026;71(21):215013. doi:10.1088/1361-6560/aeb8dd
BibTeX
@article{DufortGagnon2026,
author = {Dufort-Gagnon, Laura and Fischer, Jade and Chapman, Joshua and Stewart, Liam and Masella, Olivia and Carbone, Nicola and Bazalova-Carter, Magdalena},
title = {Feasibility of canine minibeam radiotherapy (MBRT) with a dual-robot kilovoltage x-ray system},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {21},
pages = {215013},
doi = {10.1088/1361-6560/aeb8dd}
}
EUVIMED