EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Band-limited implicit neural representations for diffusion-weighted imaging denoising

Yunxiang Li iD, Yan Dai iD, Yen-Peng Liao iD, Jie Deng iD, You Zhang iD

Physics in Medicine & Biology · 2026

DOI: 10.1088/1361-6560/ae2a9e ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2026. Verfasst von Yunxiang Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Signal-To-Noise Ratio, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Diffusion-weighted imaging (DWI) has significant value in disease diagnosis and treatment response monitoring, but its inherent low signal-to-noise ratio (SNR) severely affects image quality and quantification accuracy. Existing denoising techniques often blur important tissue boundary information when suppressing noise.

Methods

This study proposes a band-limited implicit neural representation (BL-INR) framework for DWI denoising. The method introduces BL positional encoding based on the frequency response characteristics of the sinc function to restrict INR models from learning high-frequency noise while maintaining strong signal representation capabilities. Furthermore, multi- b -value DWI and structural MRI from the same patient are integrated as anatomical priors, exploiting the correlation between true signals and the statistical independence of noise to achieve effective denoising. Main Results. In clinical DWI data evaluation across four anatomical regions (brain, head and neck, abdomen, and pelvis), BL-INR’s visualization results were superior to existing methods. Under extremely low SNR conditions (SNR = 1) in simulated noise experiments, BL-INR achieved a peak SNR of 35.44 and structural similarity index of 0.933, significantly outperforming other methods. Phantom denoising results showed that BL-INR achieved an average apparent diffusion coefficient value error of only 4.57 × 10 − 5 mm 2 s −1 , the smallest among all methods. Significance. BL-INR provides a novel approach for DWI denoising by limiting the frequency of INR input positional encoding. Its self-supervised learning characteristics require no paired training data and allow convenient clinical application. The method enables the derivation of accurate diffusion parameters, providing a reliable foundation for DWI-based quantitative analysis with significant clinical application value.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingSignal-To-Noise RatioImage Processing, Computer-AssistedHumansPhantoms, Imaging

Stichwörter der Autor:innen

denoisingdiffusion-weighted imagingimplicit neural representationself-supervised learning

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.

ORCID-Profile: Yunxiang Li, Yan Dai, Yen-Peng Liao, Jie Deng, You Zhang

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Li, Y., Dai, Y., Liao, Y. P., Deng, J., & Zhang, Y. (2026). Band-limited implicit neural representations for diffusion-weighted imaging denoising. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ae2a9e

Vancouver

Li Y, Dai Y, Liao YP, Deng J, Zhang Y. Band-limited implicit neural representations for diffusion-weighted imaging denoising. Physics in Medicine & Biology. 2026. doi:10.1088/1361-6560/ae2a9e

BibTeX
@article{Li2026,
  author = {Li, Yunxiang and Dai, Yan and Liao, Yen-Peng and Deng, Jie and Zhang, You},
  title = {Band-limited implicit neural representations for diffusion-weighted imaging denoising},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  doi = {10.1088/1361-6560/ae2a9e}
}
Kostenlos starten →