A practical and robust method for beam blocker-based cone beam CT scatter correction

Hehe Cui, Xiao Jiang, Wei Tang, Hsiao-Ming Lu, Yidong Yang

Physics in Medicine & Biology · 21.02.2023 · 68 (4) · 045006

DOI: 10.1088/1361-6560/acb2aa ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 06.02.2023. Verfasst von Hehe Cui und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, 230026 People's Republic of China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Algorithms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: the Fundamental Research Funds for the Central Universities, Anhui Provincial-level S&T Megaprojects.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . In the traditional beam-blocker based cone beam CT (CBCT) scatter correction, the scatter measured in the region shaded by lead strips was multiplied by a correction factor to directly represent the scatter in the unblocked region. The correction factor optimization is a tedious process and lacks an objective stop criterion. To skip the optimization process, an indirect scatter estimation method was developed and validated in phantom imaging. Approach. A beam-blocker made of lead strips was mounted between the x-ray source and object for scatter estimation. The primary signal between lead strips in the blocked region was first calculated by subtracting the measured scatter, and then used to calculate the scatter signal in the unblocked region corresponding to the same attenuation path. The calculated scatter signal was smoothed via local filtration and used to correct the measured projection in the unblocked region. Finally, the CBCT was reconstructed via Feldkamp–Davis–Kress algorithm. A Catphan and a head phantom were used to verify the performance of the proposed method in both full- and half-blocker scenarios, and with and without a bow-tie filter. Main Results . For scans without the bow-tie filter, the CT number error was reduced to 3.97 ± 2.27 and 5.51 ± 3.90 HU in the full- and half-blocker scenarios, respectively, for the Catphan, and to 4.01 ± 2.18 and 7.97 ± 4.05 HU for the head phantom. When the bow-tie filter was applied, the CT number error was reduced to 2.29 ± 1.42 and 6.72 ± 0.77 HU in the full- and half-blocker scenarios, respectively, for the Catphan, and 2.35 ± 1.25 and 4.96 ± 1.89 HU for the head phantom. Significance . The proposed method effectively avoids the influence of the inserted beam blocker itself on the scatter intensity estimation, and proves a more practical and robust way for the beam-blocker based scatter correction in CBCT scanning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedAlgorithmsScattering, RadiationPhantoms, ImagingCone-Beam Computed TomographyCarmustineArtifacts

Stichwörter der Autor:innen

beam blockercone beam CTscatter correction

Substanzen

Carmustine

Autor:innen und Institutionen

  • Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, 230026 People's Republic of China.
  • Hefei Ion Medical Center, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 231283 People's Republic of China.
  • Department of Radiation Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001 People's Republic of China.
  • School of Physical Sciences & Ion Medical Research Institute, University of Science and Technology of China, Hefei, Anhui, 230026 People's Republic of China.

Förderung

  • the Fundamental Research Funds for the Central Universities
  • Anhui Provincial-level S&T Megaprojects

Zitieren

APA

Cui, H., Jiang, X., Tang, W., Lu, H. M., & Yang, Y. (2023). A practical and robust method for beam blocker-based cone beam CT scatter correction. Physics in Medicine & Biology, 68(4), 045006. https://doi.org/10.1088/1361-6560/acb2aa

Vancouver

Cui H, Jiang X, Tang W, Lu HM, Yang Y. A practical and robust method for beam blocker-based cone beam CT scatter correction. Physics in Medicine & Biology. 2023;68(4):045006. doi:10.1088/1361-6560/acb2aa

BibTeX
@article{Cui2023,
  author = {Cui, Hehe and Jiang, Xiao and Tang, Wei and Lu, Hsiao-Ming and Yang, Yidong},
  title = {A practical and robust method for beam blocker-based cone beam CT scatter correction},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  volume = {68},
  number = {4},
  pages = {045006},
  doi = {10.1088/1361-6560/acb2aa}
}
Kostenlos starten →