Impact of user experience on intraocular pressure measurements in normotensive dogs using the ICare Tonovet tonometer – an interobserver study

Lynn-Helen Kindler, Martin Kramer, Stefan Kindler

Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere · 01.08.2026 · 54 (04) · 241-250

DOI: 10.1055/a-2899-4592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere, erschienen am 01.08.2026. Verfasst von Lynn-Helen Kindler und 2 weiteren Autor:innen. Beteiligte Einrichtung: AniCura Wiesbaden-Schierstein GmbH, Germany. Hauptthemen laut MEDLINE: Intraocular Pressure, Tonometry, Ocular.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the impact of user experience on intraocular pressure (IOP) measurements in handheld rebound tonometry using the ICare Tonovet tonometer. Material and methods Intraocular pressure (IOP) measurements were taken on 151 non-glaucomatous eyes of 82 dogs under general anesthesia. In each dog, tonometry was performed with the ICare Tonovet rebound tonometer by 3 examiners with different levels of experience in usage of the device. One examiner had been performing rebound tonometry for 20 years, one examiner had been performing rebound tonometry for 2 years and one examiner had never used a rebound tonometer prior to this study. To prevent the inexperienced examiner from becoming experienced, every 10 dogs a different inexperienced examiner was asked to perform the measurements. Statistical analysis was performed using Scatterplot, Pearson Correlation, simple linear correlation, Bland-Altman-Plot as well as an analysis of variance (ANOVA) and a Tukey-test.

Results

A significant positive correlation was found between inter-user IOP measurements. User experience did not have a significant impact on intraocular pressure measurements.

Conclusions

In this study, which was performed on anesthetized dogs, IOP measurements using the ICare Tonovet rebound tonometer are not significantly impacted by the experience of the examiner. Clinical relevance Inexperienced examiners can obtain reliable IOP measurements using the ICare Tonovet rebound tonometer in a clinical setting comparable to the conditions in this study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureTonometry, OcularAnimalsDogsObserver VariationFemaleMale

Autor:innen und Institutionen

  • AniCura Wiesbaden-Schierstein GmbH, Germany.
  • Department of Veterinary Clinical Sciences, Clinic for Small Animals, Surgery, Justus-Liebig-University Giessen, Giessen, Germany.

Zitieren

APA

Kindler, L. H., Kramer, M., & Kindler, S. (2026). Impact of user experience on intraocular pressure measurements in normotensive dogs using the ICare Tonovet tonometer – an interobserver study. Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere, 54(04), 241-250. https://doi.org/10.1055/a-2899-4592

Vancouver

Kindler LH, Kramer M, Kindler S. Impact of user experience on intraocular pressure measurements in normotensive dogs using the ICare Tonovet tonometer – an interobserver study. Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere. 2026;54(04):241-250. doi:10.1055/a-2899-4592

BibTeX
@article{Kindler2026,
  author = {Kindler, Lynn-Helen and Kramer, Martin and Kindler, Stefan},
  title = {Impact of user experience on intraocular pressure measurements in normotensive dogs using the ICare Tonovet tonometer – an interobserver study},
  journal = {Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere},
  year = {2026},
  volume = {54},
  number = {04},
  pages = {241--250},
  doi = {10.1055/a-2899-4592}
}