EUVIMEDEUVIMED entdecken
Crossref

Robotic-Assisted C2 Laminar Screw Placement: Initial Experience and Accuracy Evaluation

Yuki Yamamoto iD, Takashi Fujishiro, Fumiya Adachi, Takuya Obo, Sachio Hayama, Masashi Neo, Shuhei Otsuki

Journal of Neurological Surgery Part A: Central European Neurosurgery · 01.07.2026 · 87 (04) · 287-293

DOI: 10.1055/a-2840-7567 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurological Surgery Part A: Central European Neurosurgery, erschienen am 01.07.2026. Verfasst von Yuki Yamamoto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan. Hauptthemen laut MEDLINE: Spinal Fusion, Robotic Surgical Procedures, Cervical Vertebrae, Pedicle Screws. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The anchor at C2 often serves as a key stabilizer in cervical spine fusion surgery. Although the pedicle screw is considered the standard fixation method at C2, the laminar screw is also a widely used alternative due to its biomechanical stability, comparable to that of C2 PS. However, malpositioning of C2 LS carries a risk of neural injury and compromised fixation stability, and the use of surgical assistance has been reported to improve placement accuracy. The robotic system is a relatively new technology for PS placement, and its application has recently expanded to the cervical spine. The present study aimed to investigate the accuracy of C2 laminar screw placement with robot assistance. This prospective study evaluated 11 C2 laminar screws in 11 patients who underwent cervical fusion surgery with the robot assistance between March 2024 and June 2025. All 11 C2 laminar screws were successfully placed with no cortical breaches and no screw-related complications. The mean deviations at both the entry point and at a depth of 20 mm were less than 1.0 mm in both the axial and sagittal planes. The results of this study suggest that the robotic system is a potential tool to facilitate accurate C2 laminar screw placement in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FusionRobotic Surgical ProceduresCervical VertebraePedicle ScrewsBone ScrewsHumansFemaleProspective StudiesMaleMiddle AgedAgedAdult

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.

ORCID-Profile: Yuki Yamamoto

Zitieren

APA

Yamamoto, Y., Fujishiro, T., Adachi, F., Obo, T., Hayama, S., Neo, M., & Otsuki, S. (2026). Robotic-Assisted C2 Laminar Screw Placement: Initial Experience and Accuracy Evaluation. Journal of Neurological Surgery Part A: Central European Neurosurgery, 87(04), 287-293. https://doi.org/10.1055/a-2840-7567

Vancouver

Yamamoto Y, Fujishiro T, Adachi F, Obo T, Hayama S, Neo M, et al. Robotic-Assisted C2 Laminar Screw Placement: Initial Experience and Accuracy Evaluation. Journal of Neurological Surgery Part A: Central European Neurosurgery. 2026;87(04):287-293. doi:10.1055/a-2840-7567

BibTeX
@article{Yamamoto2026,
  author = {Yamamoto, Yuki and Fujishiro, Takashi and Adachi, Fumiya and Obo, Takuya and Hayama, Sachio and Neo, Masashi and Otsuki, Shuhei},
  title = {Robotic-Assisted C2 Laminar Screw Placement: Initial Experience and Accuracy Evaluation},
  journal = {Journal of Neurological Surgery Part A: Central European Neurosurgery},
  year = {2026},
  volume = {87},
  number = {04},
  pages = {287--293},
  doi = {10.1055/a-2840-7567}
}
Kostenlos starten →