Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Kaihang Luo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Spine Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China. Hauptthemen laut MEDLINE: Cervical Vertebrae, Spinal Fusion, Robotic Surgical Procedures, Pedicle Screws. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aims to evaluate the accuracy and safety of C1 lateral mass and upper cervical pedicle screw placement assisted by the TiRobot II system. METHODS: Ten patients who underwent cervical spine surgery assisted by the TiRobot II system were included. Screw accuracy was assessed using the Gertzbein-Robbins scale and by comparing the final screw positions with pre-planned trajectories. Deviations in screw tip, tail, and angle were recorded. Clinical data, including symptoms, surgical outcomes, and postoperative follow-up, were collected. Neurological improvement was evaluated using pre- and post-operative mJOA scores, with recovery rates calculated by Hirabayashi's method to assess outcomes 3 months after surgery. RESULTS: A total of 30 screws were placed in 10 patients. All screws (30/30) were within the clinically acceptable range, with 93.33% (28 screws) classified as Grade A and 6.67% (2 screws) as Grade B. In the sagittal plane, the average tip deviation was 1.82 ± 0.79 mm, tail deviation 1.64 ± 0.60 mm, and angular deviation 1.92 ± 1.39°. In the axial plane, tip deviation was 1.96 ± 0.87 mm, tail deviation 1.92 ± 0.65 mm, and angular deviation 2.01 ± 1.07°. The average surgery time was 318.80 ± 66.07 min, with a mean EBL of 205.00 ± 55.03 mL. Postoperative mJOA scores significantly improved from 8.10 ± 1.97 to 12.60 ± 1.78 (p < 0.05), with a 52 ± 14% recovery rate. All patients showed significant symptom improvement. CONCLUSION: The TiRobot II system demonstrates the capability to precisely execute pre-planned trajectories and improves the accuracy and safety of C1 lateral mass and upper cervical screw placement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cervical VertebraeSpinal FusionRobotic Surgical ProceduresPedicle ScrewsHumansFemaleMiddle AgedMaleAdultAgedTreatment Outcome

Stichwörter der Autor:innen

C1 lateral mass screwPedicle screwRobot assisted surgeryTiRobotUpper cervical surgery

Autor:innen und Institutionen

  • Department of Spine Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
  • Department of Ophthalmology, The University of Hong Kong Sheznhen Hospital, Shenzhen, Guangdong, China.
  • Department of Spine Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China. cuishb3@mail.sysu.edu.cn.

ORCID-Profile: Shangbin Cui

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Luo, K., Zou, X., Chen, W., Cui, S., Liu, S., Chen, L., & Zhou, L. (2025). Robotic assistance for upper cervical instrumentation: report on accuracy and safety. European Spine Journal. https://doi.org/10.1007/s00586-024-08510-4

Vancouver

Luo K, Zou X, Chen W, Cui S, Liu S, Chen L, et al. Robotic assistance for upper cervical instrumentation: report on accuracy and safety. European Spine Journal. 2025. doi:10.1007/s00586-024-08510-4

BibTeX
@article{Luo2025,
  author = {Luo, Kaihang and Zou, Xuenong and Chen, Wei and Cui, Shangbin and Liu, Shaoyu and Chen, Liuyun and Zhou, Lin},
  title = {Robotic assistance for upper cervical instrumentation: report on accuracy and safety},
  journal = {European Spine Journal},
  year = {2025},
  doi = {10.1007/s00586-024-08510-4}
}