EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudie

A prospective multicentric trial on accuracy, efficiency, safety, and outcomes of robot-assisted thoracic pedicle screw fixation

Satish Kripalani, Jacob Oh, S Vidyadhara, Bharat Dave, Wayne Yap, Mirant Dave, Krishna Chaitnya, Saw Lim Beng, H S Chhabra

Journal of Robotic Surgery · 26.05.2026 · 20 (1)

DOI: 10.1007/s11701-026-03495-2 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 26.05.2026. Verfasst von Satish Kripalani und 8 weiteren Autor:innen. Beteiligte Einrichtung: Robotic Spine FellowSpine Services, Sri Balaji Action Medical Institute, New Delhi, India. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Pedicle Screws, Thoracic Vertebrae, Spinal Fusion. Die Arbeit nennt 17 Literaturangaben. Gefördert von: India Medtronic Private Limited.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pedicle screw fixation is the gold standard for thoracic spine stabilization, but its accuracy is critical due to neurological and vascular complication risks. Robotic-assisted techniques show promise in improving accuracy and reducing radiation, but thoracic-specific evidence is limited. This prospective multicentric observational cohort study involves 6 high-volume centers. 100 adult patients (18–65 years) undergoing robot-assisted thoracic pedicle screw fixation will be recruited. The standardized workflow includes positioning, robotic arm mounting, registration (CT-to-fluoroscopy or scan-and-plan), and screw insertion using powered instrumentation. Data collection will cover preoperative demographics, intraoperative parameters (operative time, radiation exposure, blood loss), and postoperative outcomes. Accuracy will be assessed via the Gertzbein-Robbins grading system on postoperative CT or O-arm scans. Efficiency metrics will cover registration, planning, and screw insertion times. Clinical outcomes (VAS, ODI, SRS-22, patient satisfaction) will be evaluated at 3, 6, and 12 months. This multicentric trial will provide real-world evidence on robot-assisted thoracic pedicle screw fixation. The expectation is to develop a standardized workflow, yielding significantly higher screw placement accuracy than conventional techniques, while achieving comparable clinical outcomes. Knowledge of Robotic pedicle screw fixation utility specific to the thoracic spine is limited. This study contributes by evaluating and comparing the two registration techniques (CT-to-Fluoroscopy and Scan-and-Plan), and assessing the accuracy, safety, efficiency, and clinical outcomes of robot-assisted thoracic pedicle screw placement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresPedicle ScrewsThoracic VertebraeSpinal FusionHumansProspective StudiesAdultMiddle AgedFemaleAgedAdolescentMaleTreatment OutcomeYoung AdultOperative Time

Stichwörter der Autor:innen

AccuracyMulticentric trialRobotic spine surgeryThoracic pedicle screwWorkflow standardization

Autor:innen und Institutionen

  • Robotic Spine FellowSpine Services, Sri Balaji Action Medical Institute, New Delhi, India.
  • Department of Orthopaedic Surgery, Tan Tock Seng Hospital, Novena, Singapore.
  • Robotic Spine Surgery Manipal Hospitals, Old Airport Road, Bengaluru, India.
  • Head of Department at Stavya Spine Hospital and Research Institutex, Ahmedabad, Gujarat, India.
  • Consultant at Tan Tock Seng Hospital, Novena, Singapore.
  • Stavya Spine Hospital and Research Institute, Ahmedabad, Gujarat, India.

Förderung

  • India Medtronic Private Limited

Zitieren

APA

Kripalani, S., Oh, J., Vidyadhara, S., Dave, B., Yap, W., Dave, M., Chaitnya, K., Beng, S. L., & Chhabra, H. S. (2026). A prospective multicentric trial on accuracy, efficiency, safety, and outcomes of robot-assisted thoracic pedicle screw fixation. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03495-2

Vancouver

Kripalani S, Oh J, Vidyadhara S, Dave B, Yap W, Dave M, et al. A prospective multicentric trial on accuracy, efficiency, safety, and outcomes of robot-assisted thoracic pedicle screw fixation. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03495-2

BibTeX
@article{Kripalani2026,
  author = {Kripalani, Satish and Oh, Jacob and Vidyadhara, S and Dave, Bharat and Yap, Wayne and Dave, Mirant and Chaitnya, Krishna and Beng, Saw Lim and Chhabra, H S},
  title = {A prospective multicentric trial on accuracy, efficiency, safety, and outcomes of robot-assisted thoracic pedicle screw fixation},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1007/s11701-026-03495-2}
}
Kostenlos starten →