Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-dimensional–printed Fixateur Externe Type 1
Veterinary and Comparative Orthopaedics and Traumatology · 01.07.2026 · 39 (04) · 248-256
DOI: 10.1055/a-2749-6487 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.07.2026. Verfasst von Felix Marten und 2 weiteren Autor:innen. Beteiligte Einrichtung: Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Hannover, Germany. Hauptthemen laut MEDLINE: Tibial Fractures, Printing, Three-Dimensional, External Fixators, Fracture Fixation. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
This study aimed to evaluate percutaneous reduction of feline tibial fractures (gap model) using a three-dimensional–printed external skeletal fixator (jig) and assess the contralateral tibia as a template for virtual planning. Postmortem computed tomography (CT) was performed on 11 skeletally mature feline specimens. A mid-shaft tibial fracture gap model was created, followed by the placement of two lead-marked K-wires per fragment. The DICOMS images of repeated CT scans were imported into the virtual planning software to design a specimen-specific jig using the contralateral side as a template. The jig housed the leads and acted as a connecting bar to facilitate fracture reduction. Post-procedure radiography and CT were performed to evaluate fracture reduction. A total of 22 tibiae of 11 cats were reduced using a jig. There was an average difference of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Hannover, Germany.
Zitieren
APA
Marten, F., Kramer, S., & Huels, N. (2026). Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-dimensional–printed Fixateur Externe Type 1. Veterinary and Comparative Orthopaedics and Traumatology, 39(04), 248-256. https://doi.org/10.1055/a-2749-6487
Vancouver
Marten F, Kramer S, Huels N. Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-dimensional–printed Fixateur Externe Type 1. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(04):248-256. doi:10.1055/a-2749-6487
BibTeX
@article{Marten2026,
author = {Marten, Felix and Kramer, Sabine and Huels, Nikolaus},
title = {Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-dimensional–printed Fixateur Externe Type 1},
journal = {Veterinary and Comparative Orthopaedics and Traumatology},
year = {2026},
volume = {39},
number = {04},
pages = {248--256},
doi = {10.1055/a-2749-6487}
}
EUVIMED