Use of inverted hybrid external fixator constructs for the stabilisation of juxta‐articular appendicular long bone fractures in 20 dogs and 2 cats
Australian Veterinary Journal · 2025
DOI: 10.1111/avj.70042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Australian Veterinary Journal, 2025. Verfasst von L C Brooks und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA. Hauptthemen laut MEDLINE: External Fixators, Fracture Fixation, Tibial Fractures, Femoral Fractures. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Aim
The aim of this case series was to review clinical outcomes and complications associated with the use of inverted circular‐linear hybrid external skeletal fixator constructs with the ring positioned proximally in order to stabilise fractures with short proximal fracture segments. Materials and Methods The medical records of dogs and cats with proximal juxta‐articular fractures managed using an inverted hybrid construct at three institutions between December 2008 and October 2023 were reviewed. Data regarding animals' signalment, fracture description, construct configuration, subjective assessment of reduction and alignment, time to fixator removal and functional outcome were recorded at the time of the last clinical evaluation or via a follow‐up phone conversation with the owner. Restoration of alignment of the healed bone was objectively assessed after fixator removal by comparison of joint orientation angles between the fractured and contralateral bone.
Results
Twenty dogs and two cats underwent fracture stabilisation with an inverted hybrid construct, including 18 tibial fractures (82%), three humeral fractures (14%) and one femoral fracture (4%). Postoperative reduction and alignment was subjectively considered anatomic in six fractures, near‐anatomic in five fractures and acceptable in 11 fractures. Median time to fixator removal was 4.5 weeks (range: 2–20 weeks). Pin or wire tract inflammation developed in nine dogs and was the primary complication occurring during the postoperative convalescent period. Owners of 16 animals were contacted by telephone 7–88 months (median: 37 months) following surgery. Fourteen of those animals had no lameness, whereas two owners reported that their dog had an occasional, subtle weight‐bearing lameness. All owners were highly satisfied with the outcome of their pet's surgery.
Discussion
This descriptive case series illustrates the utility of novel inverted hybrid constructs for stabilising proximal juxta‐articular appendicular long bone fractures in small animals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA.
- Animal Referral Hospital, Brisbane, Queensland, Australia.
- Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, Wisconsin, USA.
ORCID-Profile: L C Brooks, D D Lewis
Zitieren
APA
Brooks, L. C., Lewis, D. D., Wilson, L., & Bleedorn, J. A. (2025). Use of inverted hybrid external fixator constructs for the stabilisation of juxta‐articular appendicular long bone fractures in 20 dogs and 2 cats. Australian Veterinary Journal. https://doi.org/10.1111/avj.70042
Vancouver
Brooks LC, Lewis DD, Wilson L, Bleedorn JA. Use of inverted hybrid external fixator constructs for the stabilisation of juxta‐articular appendicular long bone fractures in 20 dogs and 2 cats. Australian Veterinary Journal. 2025. doi:10.1111/avj.70042
BibTeX
@article{Brooks2025,
author = {Brooks, L C and Lewis, D D and Wilson, L and Bleedorn, J A},
title = {Use of inverted hybrid external fixator constructs for the stabilisation of juxta‐articular appendicular long bone fractures in 20 dogs and 2 cats},
journal = {Australian Veterinary Journal},
year = {2025},
doi = {10.1111/avj.70042}
}
EUVIMED