In Vitro Evaluation of a Device to Assess Acetabular Cup Position by Sagittal Plane Radiography

W Michael Karlin, Ross Lirtzman, Michael P Kowaleski

Veterinary and Comparative Orthopaedics and Traumatology · 01.03.2026 · 39 (02) · 075-080

DOI: 10.1055/a-2651-6297 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.03.2026. Verfasst von W Michael Karlin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Cummings School of Veterinary Medicine at Tufts University, North Grafton, Massachusetts, United States. Hauptthemen laut MEDLINE: Acetabulum, Radiography, Hip Prosthesis, Arthroplasty, Replacement, Hip. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study was to compare the calculated angle of lateral opening (ALO) and open-face version obtained using an acetabular cup position assessment device (CPAD) to the known ALO and open-face version of an acetabular component. The null hypothesis was that there would be no significant differences between the ALO and open-face versions using the CPAD compared with the known values. Radiographic images simulating a sagittal plane pelvis were obtained with a BFX™ acetabular component containing a CPAD mounted on a plexiglass jig with a dual-plane inclinometer. Images were obtained at an open-face version of 0 degrees with ALO at 30, 40, 45, 50, and 60 degrees, repeated in triplicate, and were randomized. Measurements of the CPAD bars were used to calculate the open-face version, and ALO measurements were compared using a paired t-test with a p-value set at p < 0.05. Agreement was assessed with a Lin's Concordance Correlation Coefficient. The calculated ALO was not significantly different from the known ALO (p = 0.608) and showed near-perfect correlation of the ALO with a Lin's Concordance Correlation Coefficient (R c value) of 0.994. The calculated open-face version was significantly different from the known version. The results demonstrate that the CPAD is an accurate method to determine ALO in a simulated sagittal plane pelvis radiographic view.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetabulumRadiographyHip ProsthesisArthroplasty, Replacement, HipAnimals

Autor:innen und Institutionen

  • Department of Clinical Sciences, Cummings School of Veterinary Medicine at Tufts University, North Grafton, Massachusetts, United States.
  • Arizona Canine Orthopedics and Sports Medicine, Scottsdale, Arizona, United States.

Zitieren

APA

Karlin, W. M., Lirtzman, R., & Kowaleski, M. P. (2026). In Vitro Evaluation of a Device to Assess Acetabular Cup Position by Sagittal Plane Radiography. Veterinary and Comparative Orthopaedics and Traumatology, 39(02), 075-080. https://doi.org/10.1055/a-2651-6297

Vancouver

Karlin WM, Lirtzman R, Kowaleski MP. In Vitro Evaluation of a Device to Assess Acetabular Cup Position by Sagittal Plane Radiography. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(02):075-080. doi:10.1055/a-2651-6297

BibTeX
@article{Karlin2026,
  author = {Karlin, W Michael and Lirtzman, Ross and Kowaleski, Michael P},
  title = {In Vitro Evaluation of a Device to Assess Acetabular Cup Position by Sagittal Plane Radiography},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  volume = {39},
  number = {02},
  pages = {075--080},
  doi = {10.1055/a-2651-6297}
}
Kostenlos starten →