Acetabular cup orientation differs across surgical approaches in primary total hip arthroplasty: a retrospective analysis

Clara Chimeno-Pigrau, Jenaro A Fernández-Valencia, Alfonso Alías, Adrià Serra, Andrés Combalia, Ernesto Muñoz-Mahamud

International Orthopaedics · 2026

DOI: 10.1007/s00264-026-06873-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Orthopaedics, 2026. Verfasst von Clara Chimeno-Pigrau und 5 weiteren Autor:innen. Beteiligte Einrichtung: Departament de Cirurgia i Especialitats Medicoquirúrgiques, Facultat de Medicina i Ciències de la Salut, University of Barcelona, Barcelona, Spain. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Acetabulum, Hip Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitat de Barcelona.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Accurate acetabular cup positioning is crucial in primary total hip arthroplasty (THA), as malposition is associated with instability and early failure. We hypothesized that acetabular cup orientation may differ according to the surgical approach used. The aim of this study was to assess whether acetabular anteversion and inclination vary according to surgical approach and whether these differences affect the proportion of acetabular cups positioned outside reference orientation zones. Materials and methods A retrospective single-centre comparative study was conducted including 300 primary THAs performed between 2018 and 2022. A stratified random sample of 100 hips per approach was selected: posterolateral (PLA), direct lateral (DLA), and direct anterior (DAA). Cup inclination and anteversion were measured on standardized postoperative radiographs using calibrated digital software. Positioning was analyzed according to the safe zones described by Lewinnek and Reina, as well as the zone corresponding to the lowest observed dislocation ratio reported by Esposito et al. Continuous and categorical variables were compared using appropriate statistical tests ( p < 0.05).

Results

Mean inclination and anteversion for the overall cohort were 41.5° and 17.6°, respectively. Significant differences were observed between approaches for both inclination ( p < 0.001) and anteversion ( p = 0.011), with the DLA demonstrating lower mean anteversion compared with the PLA and DAA. No significant differences were observed in the proportion of cups positioned within the Lewinnek safe zone ( p = 0.276). However, significant differences were observed in the proportion of cups within the Reina target zone ( p = 0.0015) and within the zone centred on 48° inclination and 24° anteversion (± 10°) derived from Esposito et al. ( p = 0.0004).

Conclusion

Acetabular cup positioning appears to vary according to surgical approach in primary THA, particularly regarding anteversion, with the PLA demonstrating higher mean anteversion and the DLA lower values. However, these differences did not translate into clinically relevant differences in positioning within established reference orientation zones according to widely used criteria.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipAcetabulumHip ProsthesisHumansRetrospective StudiesFemaleMaleAgedHip JointRadiography

Stichwörter der Autor:innen

Acetabular cup positioningCup anteversionSafe zoneSurgical approachTotal hip arthroplasty

Autor:innen und Institutionen

  • Departament de Cirurgia i Especialitats Medicoquirúrgiques, Facultat de Medicina i Ciències de la Salut, University of Barcelona, Barcelona, Spain.
  • Department of Orthopaedics and Trauma Surgery, Hospital Clínic de Barcelona, Barcelona, Spain.
  • Departament de Cirurgia i Especialitats Medicoquirúrgiques, Facultat de Medicina i Ciències de la Salut, University of Barcelona, Barcelona, Spain. combalia@ub.edu.
  • Department of Orthopaedics and Trauma Surgery, Hospital Clínic de Barcelona, Barcelona, Spain. combalia@ub.edu.

Förderung

  • Universitat de Barcelona

Zitieren

APA

Chimeno-Pigrau, C., Fernández-Valencia, J. A., Alías, A., Serra, A., Combalia, A., & Muñoz-Mahamud, E. (2026). Acetabular cup orientation differs across surgical approaches in primary total hip arthroplasty: a retrospective analysis. International Orthopaedics. https://doi.org/10.1007/s00264-026-06873-5

Vancouver

Chimeno-Pigrau C, Fernández-Valencia JA, Alías A, Serra A, Combalia A, Muñoz-Mahamud E. Acetabular cup orientation differs across surgical approaches in primary total hip arthroplasty: a retrospective analysis. International Orthopaedics. 2026. doi:10.1007/s00264-026-06873-5

BibTeX
@article{ChimenoPigrau2026,
  author = {Chimeno-Pigrau, Clara and Fernández-Valencia, Jenaro A and Alías, Alfonso and Serra, Adrià and Combalia, Andrés and Muñoz-Mahamud, Ernesto},
  title = {Acetabular cup orientation differs across surgical approaches in primary total hip arthroplasty: a retrospective analysis},
  journal = {International Orthopaedics},
  year = {2026},
  doi = {10.1007/s00264-026-06873-5}
}
Kostenlos starten →