EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic change of acetabular component position in total hip arthroplasty based on the spinopelvic classification: a prospective radiographic study

Shigeo Hagiwara, Yuya Kawarai, Junichi Nakamura, Yuki Shiko, Rui Hirasawa, Seiji Ohtori

European Journal of Orthopaedic Surgery & Traumatology · 29.08.2024 · 34 (8) · 3931-3937

DOI: 10.1007/s00590-024-04079-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 29.08.2024. Verfasst von Shigeo Hagiwara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-Ku, Chiba, 260-8670, Japan. s_hagiwara@chiba-u…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Acetabulum, Radiography, Hip Prosthesis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chiba Foundation for Health Promotion and Disease Prevention.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Recent studies have proposed optimizing the position of the acetabular component based on spinal deformity and stiffness classification to avoid mechanical complication after total hip arthroplasty (THA). The aim of this study was to characterize the dynamic changes in cup alignment post-THA based on the spinopelvic classification and to evaluate the efficacy of cup placement of preventing dislocation.

Methods

This prospective study included a total of 169 consecutive patients awaiting THA who were classified into four groups based on spinal deformity (pelvic incidence minus lumbar lordosis) and spinal stiffness (change in sacral slope from the standing to seated positions). The cups were aligned based on the group with fluoroscopy. Additionally, postoperative radiographic inclination (RI), radiographic anteversion (RA) in standard anteroposterior radiograph, and lateral anteinclination (AI) in sitting and standing positions were measured. The cumulative incidence of dislocation was evaluated at a follow-up two years post-THA.

Result

RA was significantly greater in the group with normal spine alignment and stiff spine than in other groups ( P = 0.0006), and AI in the sitting position was lower than in other groups ( P = 0.012). Standing AI did not significantly differ between the groups. One posterior dislocation occurred during the study period (0.6%).

Conclusion

AI in the sitting position was lower in patients with normal spinal alignment and stiff spine despite larger RA in the standard anteroposterior radiographs. Consequently, with more anteversion in the normal spinal alignment and stiff spine group, spinopelvic parameters can help guide cup placement to prevent short-term dislocation post-THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipAcetabulumRadiographyHip ProsthesisHumansFemaleMaleProspective StudiesAgedMiddle AgedPostoperative ComplicationsHip DislocationSpineLordosisSitting PositionStanding Position

Stichwörter der Autor:innen

DislocationRisk factorSpinal alignmentSpinal flexibilityTotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-Ku, Chiba, 260-8670, Japan. s_hagiwara@chiba-u.jp.
  • Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-Ku, Chiba, 260-8670, Japan.
  • Biostatistics Section, Clinical Research Center, Chiba University Hospital, Chiba, Japan.

Förderung

  • Chiba Foundation for Health Promotion and Disease Prevention

Zitieren

APA

Hagiwara, S., Kawarai, Y., Nakamura, J., Shiko, Y., Hirasawa, R., & Ohtori, S. (2024). Dynamic change of acetabular component position in total hip arthroplasty based on the spinopelvic classification: a prospective radiographic study. European Journal of Orthopaedic Surgery & Traumatology, 34(8), 3931-3937. https://doi.org/10.1007/s00590-024-04079-2

Vancouver

Hagiwara S, Kawarai Y, Nakamura J, Shiko Y, Hirasawa R, Ohtori S. Dynamic change of acetabular component position in total hip arthroplasty based on the spinopelvic classification: a prospective radiographic study. European Journal of Orthopaedic Surgery & Traumatology. 2024;34(8):3931-3937. doi:10.1007/s00590-024-04079-2

BibTeX
@article{Hagiwara2024,
  author = {Hagiwara, Shigeo and Kawarai, Yuya and Nakamura, Junichi and Shiko, Yuki and Hirasawa, Rui and Ohtori, Seiji},
  title = {Dynamic change of acetabular component position in total hip arthroplasty based on the spinopelvic classification: a prospective radiographic study},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2024},
  volume = {34},
  number = {8},
  pages = {3931--3937},
  doi = {10.1007/s00590-024-04079-2}
}
Kostenlos starten →