A correction factor is needed for the intraoperative measurement of cup inclination in total hip arthroplasty

Kai Hoffeld, Maximilian Lenz, Inken Meiss, Peer Eysel, Johannes Oppermann

Technology and Health Care · 2024

DOI: 10.3233/thc-230651 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Kai Hoffeld und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The cup inclination in total hip arthroplasty is key to minimising complications. Stereometric effects (parallax) in two-dimensional projections can alter angle measurements. Even for different approaches, fluoroscopy causes different results in the measurement of inclination. A previous study has introduced a corrective factor for intraoperative radiographic cup inclination measurements compared to the postoperative standing radiographs. OBJECTIVE: The aim of this study was to find out whether, first, the correction factor is reproducible and second, whether the correction factor is independent of the surgical approach and C-arm model used. METHODS: A series of 377 cases of primary total hip arthroplasty was reviewed. We compared the cup inclination angle in the intraoperative and postoperative radiographic images. Based on this, it was possible to specify a standard of correction factor in defined ranges. RESULTS: The mean cup inclination in intraoperative images was 37.47∘ and the mean angle in postoperative images was 41.42, resulting in a mean difference of 3.95∘ with a strong correlation (r= 0.706). CONCLUSION: An added correction factor of 4∘ should be respected in intraoperative inclination measurements to adapt for parallax. An increased correction factor of 6∘ in particularly low-positioned cups (< 31∘) and a decreased correction factor of 2∘ in particularly steeply positioned cups (> 43∘) is recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHumansAcetabulumRadiographyFibrinogen

Stichwörter der Autor:innen

Cup positioningInclinationIntraoperative fluoroscopy Level of evidence: 4THATotal hip arthroplasty

Substanzen

Fibrinogen

Zitieren

APA

Hoffeld, K., Lenz, M., Meiss, I., Eysel, P., & Oppermann, J. (2024). A correction factor is needed for the intraoperative measurement of cup inclination in total hip arthroplasty. Technology and Health Care. https://doi.org/10.3233/thc-230651

Vancouver

Hoffeld K, Lenz M, Meiss I, Eysel P, Oppermann J. A correction factor is needed for the intraoperative measurement of cup inclination in total hip arthroplasty. Technology and Health Care. 2024. doi:10.3233/thc-230651

BibTeX
@article{Hoffeld2024,
  author = {Hoffeld, Kai and Lenz, Maximilian and Meiss, Inken and Eysel, Peer and Oppermann, Johannes},
  title = {A correction factor is needed for the intraoperative measurement of cup inclination in total hip arthroplasty},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-230651}
}
Kostenlos starten →