EUVIMEDEUVIMED entdecken
Validierungsstudie

Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion

Matthew F Gong iD, Logan E Finger, Christina Letter, Soheyla Amirian, Bambang Parmanto, Michael O'Malley, Brian A Klatt, Ahmad P Tafti, Johannes F Plate

The Journal of Knee Surgery · 01.01.2025 · 38 (01) · 022-027

DOI: 10.1055/a-2388-0812 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.01.2025. Verfasst von Matthew F Gong und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania. Hauptthemen laut MEDLINE: Range of Motion, Articular, Mobile Applications, Knee Joint, Arthrometry, Articular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Knee range of motion (ROM) is an important indicator of knee function. Outside the clinical setting, patients may not be able to accurately assess knee ROM, which may impair recovery following trauma or surgery. This study aims to validate a smartphone mobile application developed to measure knee ROM compared to visual and goniometer ROM measurements. A knee ROM Android mobile application was developed to measure knee ROM. Patients ≥ 18 years old presenting to an orthopaedic clinic with native knee complaints were approached to participate. Knee ROM was measured bilaterally by an arthroplasty-trained surgeon using (1) vision, (2) goniometer, and (3) the mobile application. Measurements were compared in flexion and extension using a one-way analysis of variance with post hoc Tukey test (alpha = 0.05). Eighty-four knee ROM measurements (40 left, 44 right) were obtained in 47 patients. Median Kellgren–Lawrence grade from available radiographs was grade 3. In flexion, mobile application (117.6 ± 14.7 degrees) measurements were not significantly different from visual (116.1 ± 13.6 degrees) or goniometer (116.2 ± 13.6 degrees) measurements. In extension, mobile application (4.8 ± 7.3 degrees) measurements were significantly different from visual (1.9 ± 4.1 degrees) measurements on post hoc analysis (p < 0.01), while no differences were present compared to goniometer (3.1 ± 5.8 degrees) measurements. Our study found that a mobile application for evaluating knee ROM was noninferior to goniometer-based measurements performed by an arthroplasty-trained surgeon. Future studies will investigate this application's utility in (1) remote patient care, (2) accelerating recovery during rehabilitation, (3) detecting early postoperative complications including arthrofibrosis, and (4) adding additional functionalities to the application to provide more detail-oriented descriptive analyses of patient knee function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularMobile ApplicationsKnee JointArthrometry, ArticularHumansMaleFemaleMiddle AgedAgedAdultSmartphone

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Department of Health Information Management, School of Health and Rehabilitation Sciences University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Seidenberg School of Computer Science and Information Systems, Pace University, New York, New York.

ORCID-Profile: Matthew F Gong

Zitieren

APA

Gong, M. F., Finger, L. E., Letter, C., Amirian, S., Parmanto, B., O'Malley, M., Klatt, B. A., Tafti, A. P., & Plate, J. F. (2025). Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion. The Journal of Knee Surgery, 38(01), 022-027. https://doi.org/10.1055/a-2388-0812

Vancouver

Gong MF, Finger LE, Letter C, Amirian S, Parmanto B, O'Malley M, et al. Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion. The Journal of Knee Surgery. 2025;38(01):022-027. doi:10.1055/a-2388-0812

BibTeX
@article{Gong2025,
  author = {Gong, Matthew F and Finger, Logan E and Letter, Christina and Amirian, Soheyla and Parmanto, Bambang and O'Malley, Michael and Klatt, Brian A and Tafti, Ahmad P and Plate, Johannes F},
  title = {Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion},
  journal = {The Journal of Knee Surgery},
  year = {2025},
  volume = {38},
  number = {01},
  pages = {022--027},
  doi = {10.1055/a-2388-0812}
}
Kostenlos starten →